6.2
Main components of the AF 172 G2
1
3
4
5
11
12
6
7
2
9
8
8
13
9
10
Fig. 2:
Diagram of the main components
1 Electric cleaning drive
2 Backflush adapter: external pressure medium inlet
with external pressure and check valves
3 Inlet connection
4 Differential gauge / switch (optional)
5 Collection cone
6 Electro-pneumatic drain valve (optional)
7 Drain opening
8 Segmented element
9 Pressure channel housing
10 Electro-pneumatic backflush valve (optional)
11 Outlet connection
12 Filter housing
13 Backflush channel
6.3
Functional principle of the AF 172 G2
5
1
2
3
4
Fig. 3:
Functional principle of an automatic filter
1
The suspension flows tangentially downwards into the filter
housing.
The cyclone effect cause coarse solids to be sedimented
into the collection cone prior to the actual filtration process.
2
The suspension flows through the segmented element.
The particles contained in the suspension settle on the
outside of the element.
3
The filtered fluid enters the clean side and exits the filter.
4
A cleaning process is started when the maximum differential
pressure is reached (if an optional differential gauge / switch
is installed) or after a preset time.