16
MATCH LIGHTING PROCEDURE
1. Place an ignited lighter or lit match near the
ports, approximately 1/2" (1.25 cm) from burner
(see Figure 12D).
2. Push in and turn the side burner control knob to
'HIGH'. The burner should light immediately
(within four seconds). If it does not, extinguish
the lighter or match, turn the control knob off,
and wait 5 minutes for the gas to clear.
3. Repeat steps 1 and 2. If burner still fails to light,
refer to the Troubleshooting Guide to determine
the cause and solution.
REAR ROTISSERIE BURNER (OPTIONAL)
MATCH LIGHTING PROCEDURE
1. Open lid prior to lighting.
2. Place an ignited lighter or lit match near
the ports, approximately 1/2" (01.25 cm) from
burner (see Figure 12E).
3. Push in and turn the rotisserie burner control
knob to 'HIGH'. The burner
should light immediately (within four seconds).
If it does not turn off the control knob, extinguish the lighter or match, and wait 5
minutes for gas to clear.
4. Repeat steps 1 to 4. If burner still fails to light, refer to the Troubleshooting
Guide to determine the cause and solution.
NOTE: DO NOT USE THE MAIN BURNERS WHEN THE ROTISSERIE BURNER IS LIT.
PROPANE MODELS ONLY
If the heat output from the burner(s) seems abnormally low, it may be caused by the
regulator flow-limiting device being activated by a leak in the gas system, or improper
lighting procedures. If this is suspected, shut off the cylinder valve and all burner valves.
Perform a leak test to determine if a leak has caused the flow-limiting device to activate. If
the leak test is negative, then carefully follow the lighting procedures step-by-step,
ensuring all valves (including tank) are
off
before starting.
RELIGHTING
SAFETY WARNING
If the burner flame goes out when your grill is in operation, immediately turn off the
control valves. Wait five minutes for the gas to clear before attempting to relight the
burner. If the problem persists, refer to the Troubleshooting Guide.
SHUTTING DOWN YOUR GRILL
1. Shut off L.P. cylinder valve or natural gas main shut-off valve.
2. Shut off burner control valves.
This sequence prevents residual gas from being left in the system under pressure.
1.25 cm
NOTE: MAXIMUM WEIGHT FOR
SIDE BURNER 9kg (20 lb)
Fig. 12D