Thermal

 

 

Thermal management is an important consideration when thinking about equipment service life. Electrolytic 
capacitors within the PSU wear with time and are typically the first end

-

of

-

life failure. Keeping the operation 

temperature of key components within the PSU, such as the  electrolytic capacitors, as low as possible is para-
mount. As a general rule, for every 10°C drop in the operating temperature of the electrolytic  capacitators you 
double their lifetime, and thus the lifetime of the power supply. When looking at thermal performance it is helpful 
to test under a worst

-

case set of conditions, to ensure component temperatures are in an acceptable range for 

the required service life. Then consider the impact of operational time, load and temperature profile to estimate 
a more realistic lifetime for your PSU. 

 

 

Also, many FiDUS power supplies offer a 

Peak Power 

rating to provide for customers with pulsing loads. When 

using a peak power capability customers must consider:

 

1) 

Peak duration rating: the maximum length of time the peak can be drawn for

 

2) 

Duty cycle: the frequency with which the peak can be drawn. (e.g. 10% duty cycle, 1 second on:9 seconds 

off)

 

3) 

Average power value: datasheets will state the maximum average power acceptable with peak power PSUs. 

 

If any of these elements are exceeded the supply may overheat, with performance and lifetime suffering as a 
result.

 

Installation Advice

 

 

Conducted and radiated emissions compliance is a common application consideration. It is important to remem-
ber that even when using a properly filtered PSU, an application may still not achieve compliance if it is not de-
signed to minimise emissions. That being said, there are a number of things that can be done to optimise EMC 
performance either as best practice, or if you are struggling for compliance:

 

1) 

Connect all marked EMI ground points to earth. Often these are combined with the safety earth point (in class 

I installations), but on some power supplies there may be additional earth tags or mounting points.

 

2) 

Minimise the length of input/output wiring where possible and try to maintain max distance of the conductors 

from the PSU, to prevent noise pick up. Avoid bundling input and output cables together. A common component 
to avoid placing wiring near is the PFC inductor in power factor corrected power supplies.

 

3) 

Apply additional filtering before the PSU input (ensure consideration of which frequencies there are issues 

with before selecting a filter).  

 

4) 

When using an open frame PSU, mount the supply on a metal plate and connect EMI mounting points. 

 

5) 

In multi circuit systems, decouple the circuits locally.

 

6) 

Ferrites added between the PSU and system input connector and/or the DC output cables can help in reduc-

ing radiated noise issues in systems. If seen, issues are commonly in the 30

-

150MHz area.

 

 

For more detailed assistance, if you still have any concerns with compliance, please get in contact with our Engi-
neering department who are on hand to assist with any queries.

 

EMC

 

 

 

On installation customers must consider the required creepage and clearance distances between the PSU and 
the end

-

equipment enclosure. These distances vary depending on the installation class and safety standard 

requirements. 

 

 

For 

Class I 

installations there should be 3

-

4mm between any part of the PSU and any earthed metal part of the 

enclosure. 3mm is acceptable for IT applications, 4mm required for medical applications. In Class I installations 
the PSU earth point must be connected to system safety ground.

 

For 

Class II 

installations distances may need to be increased if being installed into a surrounding metal enclo-

sure.

 

Ensure consideration of components on the underside of the PCB or low lying spills when measuring clearance 
distances between the PSU and the end

-

equipment. Also top surface especially in tight enclosures such as 1U 

boxes. An insulation material can be used between PSU and metal if smaller gap required.

 

 

FiDUS recommends installing the PSU on 6mm stand offs typically, but check the distances.

 

Safety

 

 

All FiDUS Power engineering samples requested will arrive with a free of charge loom kit for ease of testing. 

 

 

The loom kit connects to the input/output terminals of the PSU and provides the customer with bare wire ends to 
connect with. 

 

 

The loom kits can also prove advantageous 
for ease of installation in production. Please 
contact sales if you are interested in includ-
ing the loom kit in your quotation.

 

Alternatively the input/output connector and 
mating part details can be found in the 
attached table.

 

 

Part Number

 

Mating Part Number

 

Input

 

B5P

-

VH

 

VHR5N

 

Output

 

M3 screw terminal

 

N/A

 

Loom Kit

 

RHM250 LK

 

Connectivity

 

RHM250P 

Series

  

 

20/05/20

 

Summary of Contents for RHM250P Series

Page 1: ...1 2006 A1 2013 ES60601 1 2005 R2012 CSA C22 2 No 60601 1 14 EN60601 1 2006 A1 2013 Key specifications RHM250P Series Notes Power dense 250W in 3 x 5 Remote on off and 5V stand by Latest medical approvals IEC 60601 1 3 1 and IEC 60601 1 2 4th Ed Earth leakage 300uA BF rated EN55011 Level B conducted radiated 40 to 70 C Operation 5 Year warranty Dimensions 3 x 5 x 1 46 76 2 x 127 x 37mm 250 Watts Th...

Page 2: ...inimum Typical Maximum Units Notes Conditions Efficiency 90 92 Isolation Input to Output 4000 VAC 2 x MOPP BF rated Input to Ground 1500 VAC Isolation resistance 50 MΩ Power density 11 4 W In3 MTBF 200 KHrs As per MIL HDBK 217F 25 C GB Weight 350 g General Parameter Minimum Typical Maximum Units Notes Conditions Operating temperature 40 70 C Derate linearly from 100 power at 50 C to 50 power at 70...

Page 3: ...d 240V 50Hz Surges EN61000 4 5 Installation Class 3 A 2KV 100V and 240V 50Hz 1KV L N Conducted EN61000 4 6 3 6Vrms A 80 AM 1KHz Magnetic Fields EN61000 4 8 30A m A 50 60Hz 1 min Voltage Dips EN61000 4 11 100 for 0 5 cycles 60 5 cycles 30 for 25 30 cycles interrupt 250 300 cycles and 1 sec performance criteria A A B EMC Immunity Safety standard Notes Conditions UL ES 60601 1 2005 R2012 CSA C22 2 No...

Page 4: ...ith JST VHR 5N P4 Pin Connections Pin Function 1 COM 2 Output 2 3 ON OFF 1 All dimensions shown in millimetres inches 4 Standby power output connector mates with JST housing XHP 3 and JST SXH series crimp terminals Input Pin Connections P1 Pin Function 1 Ground 2 Neutral 3 Line Output Pin Connections Pin Function P2 Vout P3 Return 3 DC output M3 screws torque to 3 lb in 30 CNm max ...

Page 5: ...mon component to avoid placing wiring near is the PFC inductor in power factor corrected power supplies 3 Apply additional filtering before the PSU input ensure consideration of which frequencies there are issues with before selecting a filter 4 When using an open frame PSU mount the supply on a metal plate and connect EMI mounting points 5 In multi circuit systems decouple the circuits locally 6 ...