![Fidelity Measurement DC-10 Operation Manual Download Page 93](http://html.mh-extra.com/html/fidelity-measurement/dc-10/dc-10_operation-manual_2287075093.webp)
93
T.2 Parameter Description Table
Parameter #
Description
Parameter
d1
PLU #
01 ~ 99
d2
Customer Code
Maximum 18 characteristics
Asterisk (*), number sign (#) and semi colon not accepted.
Blank = Nothing
d3
Customer Description
Maximum 30 characteristics
Asterisk (*), number sign (#) and semi colon not accepted.
Blank = Nothing
d4
Product Code
Maximum 18 characteristics
Asterisk (*), number sign (#) and semi colon not accepted.
Blank = Nothing
d5
Product Description
Maximum 30 characteristics
Asterisk (*), number sign (#) and semi colon not accepted.
Blank = Nothing
d6
Unit Weight
In term of g for metric version
In term of 1/1000 lb for lb version
Maximum 6 digit plus decimal. Blank = 0
d7
Low Check limit
When Check Target is = W: - Maximum 6 digit plus decimal. Blank = 0
When Check Target is = Q: - Maximum 6 digit. Blank = 0
d8
Hi Check limit
When Check Target is = W: - Maximum 6 digit plus decimal. Blank = 0
When Check Target is = Q: - Maximum 6 digit. Blank = 0
d9
Check Target
W = Weight
Q = PCS
Blank = PCS
d10
Auto Tare Type
M = Manual tare
A = auto tare
00 ~ 99 = Continuous tare in term of 1/10 second
Blank = current instrument setting.