![Fidelity Measurement DC-10 Operation Manual Download Page 29](http://html.mh-extra.com/html/fidelity-measurement/dc-10/dc-10_operation-manual_2287075029.webp)
29
Note E: -
Minimum weight value to be transmitted. Instrument will not generate any output if the actual weight
is less than the minimum output weight selected here.
Note F: -
Output format description: -
•
Lab 1 = Output in landscape direction. Refer to
Appendix C
for more information.
•
Lab 2 = Output in portrait direction. Refer to
Appendix D
& E
for more information.
•
Lab 3 = Database output mode. Refer to
Appendix F
for more information.
•
Lab 4 = Journal output format with gross and net weight of each individual transaction. Refer
to
Appendix G
for more information.
•
Lab 5 = Journal output format with time and net weight of each individual transaction. Refer
to
Appendix H
for more information.
•
LP-50/TSC/Sbarco = Output to LP-50 / TSC / Sbarco label printer. Refer to
Appendix I
~ K
for details.
Note G: -
•
Refer to
Appendix A
for Predefined PC Output Prot 1 ~ Prot 9.
•
Refer to
Appendix B
for Customized PC Output Protocol.
Note H: -
If Lab 1 is set in Print format, select line number then press
[Print/M+]
to save. Setup is then
completed.
Note I: -
If Lab 2 is set in Print format, select number of copy then press
[Print/M+]
to save. Setup is then
completed.
Note J: -
If Lab 3, 4 or 5 is set in Print format, press
[Print/M+]
to save. Setup is then completed.
Note K: -
If LP50/TSC/Sbarco is selected: -
a.
Select number of copy (1 ~ 8) and press
[Print/M+]
to continue the below setting,
b.
Select label file number (FL1 00 ~ FL1 99) to print in label format group 1 and press
[Print/M+]
to continue the below setting. FL1 00 = current transaction label printing output disabled.
c.
Select label file number (FL2 00 ~ FL2 99) to print in label format group 2 and press
[Print/M+]
to continue the below setting. FL2 00 = totalized (MR) data label printing output disabled.
8.4 Android and iOS APP
Android and iOS App are available to work with this instrument: -
•
For Android App: - Visit Google Play and search for aConnect.
•
For iOS App: - Visit Apple App Store and search for FMDirect.
These Apps support both Bluetooth and WIFI connection.
8.4.1 Settings when Using App via WIFI Connection
1.
Make sure that the optional built-in WIFI or LAN module is ordered.
2.
Set UART #3 of internal function F16 to WIFI or LAN depends on the options ordered. Then set
transmission type to CMD.
3.
Make sure that the weighing instrument and your smart device is under the same Network / SSID.
4.
Enter the IP and port number of the built-in WIFI / LAN module on the starting page of the APP.
5.
Once the IP and port numbers are entered, APP starts automatically.
Contact your dealer for support / more setting information about built-in WIFI / LAN module.