Command Definition
Command Format
Parameter
Output
Parameter Description
Start
String
Command Code
(Note D)
End
String
Read Accumulated Net Weight in 6-
digit format and without decimal
*
R0 or R1 or R2 or RA
awnt6
#
d1
6 digit without decimal
Read Accumulated Qty Value in 6-
digit format and without decimal
*
R0 or R1 or R2 or RA
aqty6
#
d1
6 digit without decimal
Read Accumulation sequence No
*
R0 or R1 or R2 or RA
aseq6
#
d1
6 digit without decimal
Note D
: -
R0 = command to read entries and result of current platform in used.
R1 = command to read entries and result of PF#1.
R2= command to read entries and result of PF#2.
RA = to read the totalized result of #PA.