![FibroLAN MetroStar MMM-01 User Reference Manual Download Page 86](http://html1.mh-extra.com/html/fibrolan/metrostar-mmm-01/metrostar-mmm-01_user-reference-manual_2286915086.webp)
loopback
Scope
All modules supporting extended loopback test
Syntax
config <
s
> <
c
> {<
loc
>} loopback <
test-type
>
{<
param
>}
Description
Perform a loopback test on the requested link.
Possible test types:
autosingle
(1 test frame),
automulti
(1000 test frames),
mantime
(time limited; param is
duration in seconds) &
mancount
(frame count limited;
param is frame count).
Default setting
N/A
Options
None
Example
MetroStar>config 3 2 loopback mantime 10
lx2sxlst
Scope
MCM1000S, GSM1000/MA
Syntax
config <
s
> <
c
> <
loc|rem
> lx2sxlst <
on|off
>
Description
Set the LX to SX LST mode.
Default setting
On
Options
None
Example
MetroStar>config 3 2 loc lx2sxlst off
lxautonego
Scope
All module LX FO ports, supporting Auto-Negotiation
Syntax
config <
s
> <
c
>
loc
lxautonego <
on|off
>
Description
Set the device’s LX FO port Auto-Negotiation mode.
Default setting
Off
Options
Command can be abbreviated. See general command
rules and guidelines for details
Example
MetroStar>config 3 2 loc lxautonego off
78