system ntp syncinterval
Scope
System
Syntax
config system ntp syncinterval <interval>
Description
Configure the timeservers automatic sync time interval in
seconds to the nearest power of two (4-14)
Default setting
10
Options
None
Example
MetroStar>config system ntp syncinterval 6
system ntp timezone
Scope
System
Syntax
config system ntp timezone <+/-h<.5>>
Description
Configure the time zone in hours, relative to UTC time,
using a half hour resolution.
Default setting
UTC+0
Options
None
Example
MetroStar>config system ntp ti2
MetroStar>config system ntp timezone –3.5
system offlinecfg
Scope
System
Syntax
view|show system offlinecfg
Description
Display the offline configuration function settings
Default setting
N/A
Options
None
Example
MetroStar>show system offlinecfg
31