![FibroLAN MetroStar MMM-01 User Reference Manual Download Page 27](http://html1.mh-extra.com/html/fibrolan/metrostar-mmm-01/metrostar-mmm-01_user-reference-manual_2286915027.webp)
offline copy2module
Scope
System
Syntax
config offline copy2module <
s
> <
c
> <
loc|rem
>
Description
Copies the offline configuration of the selected slot and
channel numbers to the physically installed device.
Note that the copy operation does not actually apply the
configuration to the device. It will be applied after a reboot.
Default setting
N/A
Options
The
all
keyword may be used to apply the command to
all offline configured devices
Example
MetroStar>config offline copy2module 1 1 loc
MetroStar>config offline copy2module all
offline reload
Scope
System
Syntax
config offline reload
Description
Reloads the saved offline configuration (non-volatile
memory) to the volatile memory. This may be useful in
cases where changes were made to the offline
configuration without saving and the user wishes to revert
back to saved configuration. This command applies to the
entire offline chassis and requires confirmation.
Default setting
N/A
Options
None
Example
MetroStar>config offline reload
19