![FibroLAN MetroStar MMM-01 User Reference Manual Download Page 76](http://html1.mh-extra.com/html/fibrolan/metrostar-mmm-01/metrostar-mmm-01_user-reference-manual_2286915076.webp)
e1 port <p> locallb
Scope
All E1 MetroStar modules
Syntax
config <
s
> <
c
> <
loc
> e1 port <
p
> locallb <
on|off
>
Description
Enable or disable local loopback on a module’s E1 port.
When enabled, E1 signals coming in on the port will be
looped back locally.
Default setting
Off
Options
None
Example
MetroStar>config 3 1 loc e1 port 1 locallb on
e1 port <p> remalb
Scope
All E1 MetroStar CPEs
Syntax
config <
s
> <
c
> <
rem
> e1 port <
p
> remalb <
on|off
>
Description
Enable or disable remote loopback on a CPE’s E1 port.
When enabled, E1 signals coming in on the corresponding
port of the MetroStar module will be looped back on the
CPE, back to the module.
Default setting
Off
Options
None
Example
MetroStar>config 3 1 rem e1 port 1 remalb on
e1 port <p> remlb
Scope
PCM110-xE1
Syntax
config <
s
> <
c
> loc e1 port <
p
> remlb <
on|off
>
Description
Sets remote loopback mode of selected port.
Default setting
Off
Options
None
Example
MetroStar>config 3 1 loc e1 port 1 remlb on