20
confIguratIon
1 click
2 click
Hold
Release
Button
1 (up)
Multilevel
Start / Stop
Change: 6th
group
Multilevel
Set: 6th
group
–
–
But-
ton 2
(down)
Multilevel
Start / Stop
Change: 6th
group
Multilevel
Stop Change:
6th group
–
–
Commands sent to association groups in Venetian Blinds Step-
By-Step Controller Mode (parameter 20 set to 6)
1 click
2 click
Hold
Release
Button
1
Multilevel
Start Up /
Stop Change:
6th group
Multilevel
Set: 6th
group
Multilevel
Start Up
Change: 7th
group
Multilevel
Stop Change:
7th group
Button
2
Multilevel
Start Down /
Stop Change:
6th group
Multilevel
Stop Change:
6th group
Multilevel
Start Down
Change: 7th
group
Multilevel
Stop Change:
7th group