29
ADVAncED PARAMETERS
150. Force calibration
By setting this parameter to 2 the device enters the calibration mode.
The parameter relevant only if the device is set to work in positioning
mode (parameter 151 set to 1, 2 or 4).
Available settings:
0
- device is not calibrated
1
- device is calibrated
2
- force device calibration
Default setting:
0
Parameter size:
1
[byte]
151. Operating mode
This parameter allows adjusting operation according to the connect-
ed device.
Available settings: 1 – roller blind (with positioning)
2 – Venetian blind (with positioning)
3 – gate (without positioning)
4 – gate (with positioning)
5 – roller blind with built-in driver
6 – roller blind with built-in driver (impulse)
Default setting:
1
Parameter size:
1
[byte]
152. Venetian blind - time of full turn of the slats
For Venetian blinds (parameter 151 set to 2) the parameter deter-
mines time of full turn cycle of the slats.
For gates (parameter 151 set to 3 or 4) the parameter determines time
after which open gate will start closing automatically (if set to 0, gate
will not close).
The parameter is irrelevant for other modes.
Available settings:
0-90000
(0 - 900s, every 0.01s) - time of turn
Default setting:
150
(1.5s)
Parameter size:
4
[bytes]