14
OPERATInG GATE MOTORS
#7: Operating gate motors
NOTE
Momentary switch
After releasing the
switch a spring auto-
matically pushes back
and disconnects the
switch)
i
The device allows to operate gate motors.
Gate motor should be connected to Q1 and Q2 terminals according
to installation diagram.
When operating gates a momentary switch may be connected to S1
terminal.
It is recommended to connect an IR barrier, an emergency stop but-
ton or any alarm mechanism to S2 terminal. Opening a contact in a
device connected to S2 terminal will always result in stopping a mo-
tor in current position.
Using momentary switch:
click S1 switch – move gate in sequence:
OPEn -> STOP -> clOSE -> STOP -> OPEn
Open S2 contact – stop movement
Automatic closing:
• After full opening – the gate will automatically start closing after
time specified in parameter 152,
• After opening S2 contacts – the gate will automatically start clos-
ing after time specified in parameter 154.