27
ADVAncED PARAMETERS
NOTE
Parameter 40 values
may be combined,
e.g. 1+2=3 means that
scenes for single and
double click are sent.
i
34. Alarm configuration - 5th slot (Heat)
This parameter determines to which alarm frames and how the device
should react. The parameters consist of 4 bytes, three most significant
bytes are set according to the official Z-Wave protocol specification.
Available settings:
1B
[MSB] - notification Type
2B
- notification Status
3B
- Event/State Parameters
4B
[lSB] - action:
0
- no action
1
- open blinds
2
- close blinds
Default setting:
[0x04, 0xFF, 0x00, 0x00]
(heat Alarm, any notification, no action)
Parameter size:
4
[bytes]
NOTE
Parameter 41 values
may be combined,
e.g. 1+2=3 means that
scenes for single and
double click are sent.
i
40. S1 switch - scenes sent
This parameter determines which actions result in sending scene IDs
assigned to them.
Available settings:
1
- Key pressed 1 time
2
- Key pressed 2 times
4
- Key pressed 3 times
8
- Key hold down and key released
Default setting:
0
Parameter size:
1
[byte]
41. S2 switch - scenes sent
This parameter determines which actions result in sending scene IDs
assigned to them.
Available settings:
1
- Key pressed 1 time
2
- Key pressed 2 times
4
- Key pressed 3 times
8
- Key hold down and key released
Default setting:
0
Parameter size:
1
[byte]
SCENE TIGGERING CONFIGURATION
NOTE
Enabling triple click
for S1 in parameter 40
disables the ability to
add/remove via S1.
i