15
Info boiler
Select "
Info boiler
" in the "
SETTINGS MENU
" to view information regarding
the devices connected to the boiler:
The table below summarizes all the possible devices that can be displayed in the "
Info
boiler
", their description, and the values that they can assume:
INFO
BOILER
INFORMATION
DESCRIPTION / VALUES
1
CH Temp
Temperatures detected by the delivery probe (SM)
DHW Temp.
Temperature detected by the sanitary hot water tank probe
(SB)
External T.
Temperature detected by the external probe (SE)
Th. Room
Room thermostat (TA) status:
ON: Closed
OFF: Open
2
Th. Safety
Safety thermostat (TS) status:
ON: Closed
OFF: Open
OpenTherm
OpenTherm communication status:
ON: Active
OFF: Not active
RS 485
RS485 communication status (cascade):
ON: Active
OFF: Not active
Press.H2O
Water pressure switch status (if present):
ON: Closed
OFF: Open
If transducer present:
PRESSURE TRANSDUCER VALUE
3
Flow H2O
Sanitary water system flow meter value
Circulator
% System circulator speed
Diverter
valve
Diverter valve status:
ON: Active
OFF: Not active
6
Th. Room2
Secondary zone room thermostat status:
ON: Closed
OFF: Open
CH Temp2
Temperatures detected by the secondary zone probe