6
MAIN TECHNICAL FEATURES
Elektra Compact 6 kW N 6 kW maximum electric power
Single-phase power supply: 230-240 V - 50 Hz
Weight: 38 kg.
Central heating system: 6 kW electric/thermal power from no.2 heating elements (no.2 of
3x1 kW).
Maximum head available to the circulator approx 7 m.
Expansion vessel capacity 9 litres.
0.3 MPa (3 bar) central heating circuit safety valve.
Maximum central heating operating pressure: 0.25 MPa (2.5 bar).
Minimum central heating circuit operating pressure: 0.06 MPa (0.6 bar).
Central heating circuit-boiler body maximum thermal safety limit: 100°C.
Elektra Compact
7-8-9
kW N
7-8-9
kW maximum electric power
Single-phase power supply: 230-240 V - 50 Hz
Weight: 3
8
kg.
Central heating system:
7-8-9
kW electric/thermal power from no.2 heating elements (no.
1
of
3x2
kW and no.1 of 3x1 kW)
.
Maximum head available to the circulator approx 7 m.
Expansion vessel capacity 9 litres.
0.3 MPa (3 bar) central heating circuit safety valve.
Maximum central heating operating pressure: 0.25 MPa (2.5 bar).
Minimum central heating circuit operating pressure: 0.06 MPa (0.6 bar).
Central heating circuit-boiler body maximum thermal safety limit: 100°C.
Elektra Compact 1
2
kW N 1
2
kW maximum electric power
Single-phase power supply: 230-240 V - 50 Hz
Weight:
39
kg.
Central heating system: 1
2
kW electric/thermal power from no.
2
heating elements (no.
2
of
3x2 kW).
Maximum head available to the circulator approx 7 m.
Expansion vessel capacity 9 litres.
0.3 MPa (3 bar) central heating circuit safety valve.
Maximum central heating operating pressure: 0.25 MPa (2.5 bar).
Minimum central heating circuit operating pressure: 0.06 MPa (0.6 bar).
Central heating circuit-boiler body maximum thermal safety limit: 100°C.
Summary of Contents for Silver Touch Elektra Compact 12 kW N
Page 2: ......
Page 42: ...41 SPARE PARTS 4 Detail view Electric Box Detail view Body Heating Elements 23 25 29 22 22 ...
Page 47: ......