17
Setting boiler
The second item "
Setting boiler
” of the "
SETTINGS MENU
" can be used to
view and modify the boiler and central heating system setting parameters. The parameters
and their meanings are described in detail in the relevant paragraph.
The menus for setting the boiler and heating system parameters have been sorted into
sub-menus according to the type of setting and access right.
The "
Installer menu
" only contains the essential parameters for the configuration
of the boiler type.
When accessed, this menu shows the "
Read parameter
"
screen:
where the parameter index is shown on the left and
its current value on the right. The value does not
appear instantaneously but is transferred each time
from the control board of the boiler. Before its
appearance, three dashes will be displayed for a few
moments "
---
“. Press
▼
(
SW6
)
[
↓
]
and
▲
(
SW7
)
[
↑
]
to scroll through the entire list of
parameters. Press
■
(
SW5
)
[SET]
to access the parameter edit screen. Finally, press
◄
(
SW3
)
[ESC]
to return to the "
PARAMETERS MENU
".
In the "
Write parameter
" screen, the index is blocked and the value is highlighted.
Press
▼
(
SW6
)
[-]
and
▲
(
SW7
)
[+]
to change
the parameter value, followed by
■
(
SW5
)
[OK]
to
save the new value. Press
◄
(
SW3
)
[ESC]
to
return to the "
Read parameter
" screen without
changing the parameter.