35/50
GB
COMPRESSOR MAINTENANCE
6
1
2
1
2
6.1.4
Replacing the air filter cartridge
Read all indicated in
Section 6.1
before starting any maintenance jobs.
Open the top panel to access inside the compressor.
Take the cover off
1
; clean the filter holder thoroughly.
Replace the cartridge of the air filter
2
and fit the cover back in place.
6.1.5
Joint
On a periodic basis, visually inspect the joint
2
based on the hours of operation indicated in the maintenance
table.
Ensure it operates silently and that there are no splits or other damages in the orange flexible part.
Proceed as follows:
Check if there are any abnormal noises during operation.
Stop the compressor.
Disconnect the power supply of the compressor by switching the main ON/OFF switch OFF and make sure
it cannot be switched ON again accidentally.
Unscrew the protection grid
1
.
Manually turn the joint and check its state.
If you notice any damages, contact an authorised Service centre of the Manufacturer to have it replaced!
If no damages or problems are noticed, screw the protection grid back in place.
Close the external maintenance panel.
Summary of Contents for AIRBLOK 40
Page 44: ...44 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 45: ...45 68 GB DRAWINGS AND DIAGRAMS 7 ...
Page 46: ...1 4 CF75G AIRBLOK40 SD ...
Page 49: ...2 4 CF75G AIRBLOK40 SD ...
Page 51: ...3 4 CF75G AIRBLOK40 SD ...
Page 53: ...4 4 CF75G AIRBLOK40 SD ...
Page 55: ...1 4 CF90LD1 AIRBLOK50 SD ...
Page 58: ...2 4 CF90LD1 AIRBLOK50 SD ...
Page 60: ...3 4 CF90LD1 AIRBLOK50 SD ...
Page 62: ...4 4 CF90LD1 AIRBLOK50 SD ...
Page 66: ...46 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 67: ...Date Job description Hours of use Operator ssignature ...