33/50
GB
COMPRESSOR MAINTENANCE
6
4
1
3
2
6.1.1
Changing the oil
Read all the information provided in
Section 6.1
before proceeding with any maintenance jobs.
Check the oil level after
500 hours
of use and then every
5000 hours
and in event once a year.
Open the front panel to access the internal parts of the compressor.
Unscrew cap
1
on the separator tank.
Take cap
2
off.
Screw the fitting with tail piece
3
(supplied with the compressor).
As the knurled fitting 1 is turned oil starts to seep out from the screw unit, therefore
use a hose and container to collect the oil.
Once all the oil has been drained remove the knurled fitting
3
and screw cap
2
manually.
Top up with oil to half way up inspection glass
4
, then screw cap
1
back on and close the compressor.
Once the oil and oil filter have been changed leave the compressor to run for roughly 5 minutes then turn
it off and check the oil level again.
Check the oil level once a month. Ensure it is half way up inspection glass
4
.
Never mix different types of oil, therefore always ensure that the circuit is completely empty
before filling-up with oil. Each time the oil is changed the filter is also to be replaced.
Summary of Contents for AIRBLOK 40
Page 44: ...44 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 45: ...45 68 GB DRAWINGS AND DIAGRAMS 7 ...
Page 46: ...1 4 CF75G AIRBLOK40 SD ...
Page 49: ...2 4 CF75G AIRBLOK40 SD ...
Page 51: ...3 4 CF75G AIRBLOK40 SD ...
Page 53: ...4 4 CF75G AIRBLOK40 SD ...
Page 55: ...1 4 CF90LD1 AIRBLOK50 SD ...
Page 58: ...2 4 CF90LD1 AIRBLOK50 SD ...
Page 60: ...3 4 CF90LD1 AIRBLOK50 SD ...
Page 62: ...4 4 CF90LD1 AIRBLOK50 SD ...
Page 66: ...46 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 67: ...Date Job description Hours of use Operator ssignature ...