20/68
GB
5
USING THE COMPRESSOR
9
1
2
8
7
5
4
10
3
6
When the request for air is greater, therefore the line pressure drops, the inverter increases the speed of
the motor, also increasing the air output. When the request for air is lower, the inverter reduces the speed
of the motor, also reducing the air output, therefore the mains pressure is held constant as the air
consumption varies.
If the request for air is very low, the compressor proceeds at the minimum speed admitted, therefore
consuming just the consumption energy required.
If the request for air is zero, the compressor enters “idle” running mode for roughly two minutes and then
it enters “STAND-BY” mode.
If the line pressure falls below the minimum pressure set, the compressor starts again to guarantee the
required air output, restoring the pressure at the correct values.
5.2
Controls, indicators and safety devices of the compressor
5.2.1
Control panel
The control panel is made up of a set of buttons required for the main operational and control functions of
the compressor.
1 GREEN LED
This points out that the compressor is powered.
2 START (I)
This button is used to turn the compressor on.
3 STOP (O)
Press this button to turn the compressor off (delayed).
4 DEFAULT
Compressor programming is exited by pressing this push button.
5 PROGRAM
Programming is enabled by pressing this push button.
6 MENU SCROLLING PUSH BUTTON
These four push buttons are used to scroll the menus displayed.
7 RESET
Press this push button to cancel a procedure or to reset an alarm, provided the cause that triggered it
has been eliminated.
8 RED LED
This points out that an alarm has tripped.
9 DIGITAL DISPLAY
The various menus are displayed and the parameters are monitored in this display.
Summary of Contents for AIRBLOK 40
Page 44: ...44 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 45: ...45 68 GB DRAWINGS AND DIAGRAMS 7 ...
Page 46: ...1 4 CF75G AIRBLOK40 SD ...
Page 49: ...2 4 CF75G AIRBLOK40 SD ...
Page 51: ...3 4 CF75G AIRBLOK40 SD ...
Page 53: ...4 4 CF75G AIRBLOK40 SD ...
Page 55: ...1 4 CF90LD1 AIRBLOK50 SD ...
Page 58: ...2 4 CF90LD1 AIRBLOK50 SD ...
Page 60: ...3 4 CF90LD1 AIRBLOK50 SD ...
Page 62: ...4 4 CF90LD1 AIRBLOK50 SD ...
Page 66: ...46 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 67: ...Date Job description Hours of use Operator ssignature ...