23/68
GB
USING THE COMPRESSOR
5
CLIENT MENU
(“> + DEFAULT” simultaneously)
To access this menu, press keys > and DEFAULT simultaneously. The CLIENT MENU enables you to
calibrate the following parameters:
1. Cut-in pressure of the compressor (Min. P.)
2. Cut-off pressure of the compressor (Max. P.)
3. Idle running time
To scroll the parameters indicated, press the “DOWN arrow” and “UP arrow” keys of the push button control
panel and press the “DEFAULT” key to exit.
1.
To change the Min. P. value (equal to 8 bar in the example given), press “PROGRAM” and enter the
replacement value in decimals, without commas using the “DOWN arrow” and “UP arrow” keys of the push
button control panel and press “PROGRAM”.
i.e.: To set Min. P. = 7.5 bar
- press “PROGRAM”
- enter “75”
- press “PROGRAM”
Note!
Min. P. Must be greater than or equal to 5.5 bar/79.8 psi
(Max. P. – Min. P.) must be greater than or equal to 1 bar/14.5 psi
To exit the menu, press the “DEFAULT” key.
2.
To change the Max. P. value (equal to 10 bar in the example given), press “PROGRAM” and enter the
replacement value in decimals, without commas using the “DOWN arrow” and “UP arrow” keys of the push
button control panel and press “PROGRAM.
Note!
Max. P. must be at least 0.5 bar/7.2 psi lower than the Alarm P.
(Max. P. – Min. P.) must be greater than or equal to 1 bar/14.5 psi
To exit the menu, press the “DEFAULT” key.
3.
Specify the idle running time of the compressor in seconds. To modify it, enter the new value using the “UP
arrow” and “DOWN arrow” keys of the push button control panel, (in seconds) and then press “PROGRAM”.
Note!
The minimum idle running time is 120 sec, the maximum value is 600 sec.
To exit the menu, press the “DEFAULT” key.
4.
Specify the value of the kwh consumed up to the current time from the last reset.(only “SD”)
Enter “0” (Zero) to reset the meter.
To exit the menu, press the “DEFAULT” key.
MIN.P.CUSTOMER
SETUP (8.0)
MAX.P.CUSTOMER
SETUP (10.0)
IDLE RUN TIME
(240)
METER SET ZERO KW
(2321)
Summary of Contents for AIRBLOK 40
Page 44: ...44 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 45: ...45 68 GB DRAWINGS AND DIAGRAMS 7 ...
Page 46: ...1 4 CF75G AIRBLOK40 SD ...
Page 49: ...2 4 CF75G AIRBLOK40 SD ...
Page 51: ...3 4 CF75G AIRBLOK40 SD ...
Page 53: ...4 4 CF75G AIRBLOK40 SD ...
Page 55: ...1 4 CF90LD1 AIRBLOK50 SD ...
Page 58: ...2 4 CF90LD1 AIRBLOK50 SD ...
Page 60: ...3 4 CF90LD1 AIRBLOK50 SD ...
Page 62: ...4 4 CF90LD1 AIRBLOK50 SD ...
Page 66: ...46 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 67: ...Date Job description Hours of use Operator ssignature ...