24/68
GB
5
USING THE COMPRESSOR
1
To summarise:
CALIBRATION LIMITS
-
Max. P. < Alarm P. - 0.5 bar/7.2 psi
-
Min. P. > 5.5 bar/79.8 psi
-
DP = (Max. P. – Min. P.) > 1 bar/14.5 psi
-
120 s < IDLE RUNNING TIME < 600 sec
- “0” to reset the meter.
The “Alarm P.” can be modified from the manufacturer’s “SETTING” menu.
ALARMS
The alarms that may trigger can be grouped in two categories:
A) Stopped ALARM (
red steady LED
)
B) Warning ALARM (
red flashing LED
)
C) INVERTER stopped and warning ALARMS (
Red steady or flashing LED
)
A) Stopped ALARM
This type of alarm
stops the compressor
and is pointed out by the
red steady LED
(ALARM on
dashboard), by a beeping buzzer and by a flashing message on the display indicating the cause for the
actual alarm.
1. When the Pressure exceeds the limit alarm pressure (case in which the increase in pressure is so quick
that the max. cut-off pressure is unable to intervene) the following appears on the display:
ALARM
PRESSURE
THE COMPRESSOR STOPS!
To reset the machine:
Once the pressure has dropped (P < Alarm P.) press the “RESET” key to set the compressor ready to
start again. At this stage the following appears on the display:
2. When the limit oil-air temperature is exceeded (T>alarm T.=105°C/221°F) the following appears on the
display:
PRESS START
TO START
ALARM
TEMPERATURE
THE COMPRESSOR STOPS!
To reset the machine:
Once the temperature has dropped by at least 10°C/18°F compared to the limit temperature, you can
RESET the compressor internally (you need to open the front hatch and then press the board RESET
button).
Summary of Contents for AIRBLOK 40
Page 44: ...44 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 45: ...45 68 GB DRAWINGS AND DIAGRAMS 7 ...
Page 46: ...1 4 CF75G AIRBLOK40 SD ...
Page 49: ...2 4 CF75G AIRBLOK40 SD ...
Page 51: ...3 4 CF75G AIRBLOK40 SD ...
Page 53: ...4 4 CF75G AIRBLOK40 SD ...
Page 55: ...1 4 CF90LD1 AIRBLOK50 SD ...
Page 58: ...2 4 CF90LD1 AIRBLOK50 SD ...
Page 60: ...3 4 CF90LD1 AIRBLOK50 SD ...
Page 62: ...4 4 CF90LD1 AIRBLOK50 SD ...
Page 66: ...46 68 GB 7 DRAWINGS AND DIAGRAMS ...
Page 67: ...Date Job description Hours of use Operator ssignature ...