E Calibration
Brewer Sensors and Keypad
POSITION Program Items
Factory set Default
Programming Range Increments Notes
E1
Ready Temp.
Offset
-3°F
-2°C
-2° to -9°F
-1° to -5° C
1°F
1°C
Compensates output to
measured temperature
E2
LLC Sensitivity
NORMAL
(“NORMAL” for most
water)
HIGH
(Biased for reverse
osmosis water or
very pure water)
NORMAL
HIGH
Liquid level control
sensitivity.
High,1300Ω is for reverse
osmosis water or very
pure water.
E3
Slow flow rate
from supply
ON
OFF/ON
/-
YES or NO
Trims fill system for low
supply or Flojet use
E4
LT Brew valve
flow rate:
1.80L
0.47G
61oz
1.05-1.60Liter
0.39-0.55G
50-71 fl.ounces
0.05L
0.01G
1 oz
Adjusts flow rate
E5
RT Brew valve
flow rate:
1.80L
0.47G
61oz
1.05-1.60Liter
0.39-0.55G
50-71 fl.ounces
0.05L
0.01G
1 oz
Adjusts flow rate
E6*
LT Bypass valve
flow rate:
1.30 liters/minute
(0.36 gallon/minute)
(46 ounces/minute)
1.10-1.65Liter
0.28-0.42G
37-54 fl.ounces
0.05L
0.01G
1 oz.
Adjusts flow rate
E7*
RT Bypass valve
flow rate:
1.30 liters/minute
(0.36 gallon/minute)
(46 ounces/minute)
1.10-1.65Liter
0.28-0.42G
37-54 fl.ounces
0.05L
0.01G
1 oz.
Adjusts flow rate
*Active if bypass is installed and activated on equipment
Use this formula to compensate for minor discrepancies in actual volume versus programmed volume.
See “PROGRAM” E4 & E5 For valve settings and calibration. Factory set brew valve flow rates are in liter/min
Default Brew Valve Flow Rate—CBS-1230 Brewers
CBS-1230
L/minute
Range
ACTUAL VOLUME
X
CURRENT
SETTING
=
NEW
SETTING
Left Brew Valve FR
1.80
1.50 L to 2.10 L
PROGRAMMED VOLUME
Right Brew Valve FR
1.80
1.50 L to 2.10 L
Use the formula above to determine the correct setting Set FR
lower
to
increase
volume,
Set FR
higher
to
decrease
volume