Fetco E1231IN-1B123-PM000 Users Manual And Operator Instructions Download Page 12

Go to fetco.com for the latest versions of all information         

Page 12

      

User Guide & Operator instructions

   

P211

e0

November 2021

 

G Counters

 

Brewer Usage, Water Filter Usage, and Statistics 

ROLE: [LT]=Permanent total for lifetime of ma[chine R]=operator resettable [User]=Input needed from operator 
Position 

Counter  Program items 

Role 

Information 

Increments 

Notes 

G1-G3 are for water filter maintenance.   Filter Life readings (G1, G2, G3) must be activated in B13 GENERAL if they are not visable and the equipment has a water filter.  

All beverage equipment must use filtered water and filter cartridges must be monitored for quality 

G1 

A, S, B  Filter Used 

[User]  0G 

Gallons/Liters 

Amount of water passed through external 

water filter.  For filter life 

G2 

A, S, B  Filter Life 

[User]  2,625Gal 10,000Liters  25 gal 100 L 

Upload published life of filter 

G3 

A, S, B  Filter Reset 

[User]  NO 

/- ,Y or N  Reset when replacing external water filter 

G4 

A, S, B  Counter Reset 

[User]  NO 

/- ,Y or N  Resets all resettable counters to zero 

G5 

A, S, B 

Choose Counter 

 

Factory set to BASIC 

       Basic=

B

 

Advanced=

A

 

Statistical=

S

 

Stored brewer component activity..  

See 

column 2, Counters

, to identify 

where counters are located. 

G10-G15 Number of brews and volumes handled. Available in BASIC counter only (G5) 

G10 

Brewer Volume  

[LT] 

Dispensed volume 

Gallons/Liters 

Total of brews and hot water dispensed 

G11 

Brewer Volume  

[R] 

G12 

Lt Brews  

[LT] 

Left side brew total 

CBS-1232 

Count 

Total brews-Left side (CBS-1232 only) 

G13 

Lt Brews  

[R] 

G14 

Rt Brews  

[LT] 

Right side brew total 

CBS-1231&CBS-1232  Count 

Total brews-Right side 

CBS-1231&CBS-1232 

G15 

Rt Brews  

[R] 

G20-G55  component use cycles and volumes handled. Available in ADVANCED counter only (G5) 

G20 

Fill Cycles  

[LT] 

Hot water tank refill 

cycles 

Count 

Cycles of hot water tank refill 

G21 

Fill Cycles  

[R] 

G22 

Fill Volume  

[LT] 

Total volume of water 

for all brews 

Gallons/Liters 

Quantity of water for brews 

G23 

Fill Volume  

[R] 

G24 

Lt Brew Cycles  

[LT] 

Left brew valve 

operation on/off 

Count 

Totalized cycles of valve operation 

(CBS-1232 only) 

G25 

Lt Brew Cycles  

[R] 

G26 

Lt Brew Volume  

[LT] 

Left brew valve  

flow through volume 

Gallons/Liters 

Totalized volume through left valve 

(CBS-1232 only) 

G27 

Lt Brew Volume  

[R] 

G28 

Rt Brew Cycles  

[LT] 

Right brew valve 

operation on/off 

Count 

Totalized cycles of valve operation 

CBS-1231&CBS-1232 

G29 

Rt Brew Cycles  

[R] 

G30 

Rt Brew Volume  

[LT] 

Right brew valve  

flow through volume 

Gallons/Liters 

Totalized volume through right valve 

CBS-1231&CBS-1232 

G31 

Rt Brew Volume  

[R] 

G32 

Lt Bypass Cycles  

[LT] 

Left bypass valve 

operation on/off 

Count 

Totalized cycles of valve operation 

(CBS-1232 only) 

G33 

Lt Bypass Cycles  

[R] 

G34 

Lt Bypass Volume  

[LT] 

Left bypass valve  

flow through volume 

Gallons/Liters 

Totalized volume through left valve 

(CBS-1232 only) 

G35 

Lt Bypass Volume  

[R] 

G36 

Rt Bypass Cycles  

[LT] 

Count 

Count 

Totalized cycles of valve operation 

CBS-1231&CBS-1232 

G37 

Rt Bypass Cycles  

[R] 

G38 

Rt Bypass Volume  

[LT] 

Right bypass valve 

flow through volume 

Gallons/Liters 

Totalized volume through right valve 

CBS-1231&CBS-1232 

G39 

Rt Bypass Volume  

[R] 

G52 

Heater Cycles  

[LT] 

ON/OFF switching for 

heating elements 

Count 

Totalized cycles of heater switching 

G53 

Heater Cycles  

[R] 

G54 

Heater On Time  

[LT] 

Total ON time for 

heating element 

Hour 

Totalized heater ON time in hours 

G55 

Heater On Time  

[R] 

G80-G91 See illustration below for batch button positions Available in STATISTICAL counter only (G5) 

G80 

Batch 10 Cycles  

[LT] 

Menu button selection 

and activation count 

Count 

Total brews-left side top button 

(CBS-1232 only) 

G81 

Batch 10 Cycles  

[R] 

G82 

Batch 20 Cycles  

[LT] 

Menu button selection 

and activation count 

Count 

Total brews-left side middle button 

(CBS-1232 only) 

G83 

Batch 20 Cycles  

[R] 

G84 

Batch 30 Cycles  

[LT] 

Menu button selection 

and activation count 

Count 

Total brews-left side bottom button 

(CBS-1232 only) 

G85 

Batch 30 Cycles  

[R] 

G86 

Batch 40 Cycles  

[LT] 

Menu button selection 

and activation count 

Count 

Total brews-right side top button 

CBS-1231&CBS-1232 

G87 

Batch 40 Cycles  

[R] 

G88 

Batch 50 Cycles  

[LT] 

Menu button selection 

and activation count 

Count 

Total brews-right side middle button 

CBS-1231&CBS-1232 

G89 

Batch 50 Cycles  

[R] 

G90 

Batch 60 Cycles  

[LT] 

Menu button selection 

and activation count 

Count 

Total brews-right side bottom button 

CBS-1231&CBS-1232 

G91 

Batch 60 Cycles  

[R] 

 

Summary of Contents for E1231IN-1B123-PM000

Page 1: ...de and Operator Instructions CBS 1231 CBS 1232 Extractor Plus Brewing System FETCO PLUS Commercial Beverage Equipment CBS 1232 CBS 1232 3 0 4 0 Extractor Plus Brewers shown with 2 2 liter Air Pot sold...

Page 2: ...y Weight Filled Weight Shipping Weight Shipping Dimensions CBS 1231 Brewer 27 3 4 in 700 mm 11 3 4 in 300 mm 20 in 520 mm 3 3 gallon 12 4 L 29 lbs 13 2 kg 55 lbs 25 0 kg 41 lbs 18 6 kg 30 x 17 x 22 76...

Page 3: ...erminal Block 1 10 9 13 0 7 7 gal 29 1 L CBS 1231PLUS 3 0 4 0 Lit er Coffee B rewers C E m odels Electrical and Output Specifications Schuko cor d and pl ug 50Hz SKU Voltage Heater C onfiguration Wire...

Page 4: ...rew basket 5 Select a batch hold the corresponding BREW button in for 1 second to start 6 STOP button will illuminate Countdown time will display Selected BREW button will flash to indicate brew is in...

Page 5: ...90 Copy Batch B13 Filter Life F14 Override Lt BBS See Page 12 A91 Copy Batch From F15 Override Rt BBS A92 PASTE To F16 Override Lt BBL F17 Override Rt BBL Left and Right top and middle batches are per...

Page 6: ...30 minutes 2 00 12 00 0 30 Default total brew time is 5 30 minutes A2 30 Prewet Perc 0 0 00 25 0 1 Percentage of total brew volume A2 40 Prewet Delay Brew pause after prewet completes 0 1 00 Min 0 10...

Page 7: ...mperature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 205 212 0 96 100 0 500 152 205 211 0 96 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 2...

Page 8: ...ncrements Notes D1 Heater SSR Test Press button 2 to test button 1 stops test Activates heater Default is 10 sec Toggle OFF or ON Energizes Heater s WARNING Service use only D2 Fill Valve Test Press b...

Page 9: ...47G 61oz 1 05 1 60Liter 0 39 0 55G 50 71 fl ounces 0 05L 0 01G 1 oz Adjusts flow rate E6 LT Bypass valve flow rate 1 30 liters minute 0 36 gallon minute 46 ounces minute 1 10 1 65Liter 0 28 0 42G 37...

Page 10: ...NO Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F10 Restore Defaults NO NO YES Reset to factory When selecting F10 RESTORE...

Page 11: ...r short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank did not refill within expected time Water supply flow rate is too low Watch for short...

Page 12: ...Volume LT Left brew valve flow through volume Gallons Liters Totalized volume through left valve CBS 1232 only G27 A Lt Brew Volume R G28 A Rt Brew Cycles LT Right brew valve operation on off Count T...

Page 13: ...en From SAVE screen Press button 2 to toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT NOTE User Settings will be erased and overwritten to factory default s...

Page 14: ...er such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polish...

Page 15: ...possible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in a position to facilitate filter replacemen...

Page 16: ...nit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or aut...

Page 17: ...1232 4 required for CBS 1231 Legs are sent from factory inside brew basket Attach legs before installing 2 Adjust dispenser locator for either 3 Liter 1 Gallon dispensing Set Dispenser Locator Shown...

Page 18: ...rts Diagram CBS 1231 Drawing 1101 00570 00 Parts CBS 1231 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE 2 1 2 legs Extends to 3 5 8 Part number 1073 00016 00 3 required for CBS 1232 4 requir...

Page 19: ...41 31 11 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 32 1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 33 1 1402 00098 10 HARNESS LOW AMP CBS 1230 UL 34 1 1046 000...

Page 20: ...ts Diagrams CBS 1232 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE Drawing 1101 00571 00 Parts CBS 1232 2 1 2 legs Extends to 3 5 8 Part number 1073 00016 00 3 required for CBS 1232 4 requir...

Page 21: ...023 00355 00 LOCATOR AIRPOT ADAPTER CBS 2230 29 1 1001 00408 00 COVER TOP CBS 2232 42 30 1 1001 00409 00 COVER UPPER BASE CBS 2232 42 31 11 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 32 1...

Page 22: ...UNDERSIZED ZINC PLATED 9 1 1107 00021 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 1 1107 00022 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 1 1107 00020 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 9 1 11...

Page 23: ...OTH LOCKWASHER 8 10 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00022 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 2 1107 00019 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 10 2 1003 00140...

Page 24: ...FITTING STRAIGHT GROMMET 400 10 1 1023 00166 00 FITTING COLD WATER INLET GROMMET DESIGN 11 2 1107 00019 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 11 2 1107 00020 00 HEATER ASSEMBLY IMMERSION 2300W 240...

Page 25: ...02 00113 00 SWITCH REED ASSEMBLY 5 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN ORANGE 6 2 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL interchangeable with 1057 00078 00 6 2 1057 00078 00...

Page 26: ...BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 00192 00 ORANGE PLUG BB HANDLE 1023 00180 00 BLUE PLUG BB HANDLE Stainless Steel Brew Basket Ref Qty Part Number Description B003218B1 Complete Stain...

Page 27: ...Go to fetco com for the latest versions of all information Page 27 User Guide Operator instructions P211e0November 2021 Wiring Diagrams SSR SSR SKU E1231US 1X117 PM001 CBS 1231 Domestic Dual Voltage...

Page 28: ...com for the latest versions of all information Page 28 User Guide Operator instructions P211e0November 2021 S S R Wiring diagram 1401 00190 10 E1231US 1A115 E1231US 1A123 E1231US 1X117 E1231IN 1B130 C...

Page 29: ...com for the latest versions of all information Page 29 User Guide Operator instructions P211e0November 2021 SSR Wiring diagram 1401 00196 10 E1232US 1B223 E1232US 1B230 E1232IN 1B223 E1232IN 1B230 CB...

Page 30: ...End of section notes N...

Reviews: