F Error Codes 

DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND CORRECTED 

Contact factory or specialized personnel for error codes  

Code  Description 

Possible Cause 

Corrective Action 

001

 

Software error-error on start up or 

corrupted software 

 

Improper start-up or shutdown

 

Restart , if still fault:  reload software

 

002 

Internal flash corrupted 

internal data memory malfunction 

Error found in 

cyclic 

redundancy check 

CRC

 

Restart , if still fault:  reload software 

If not corrected :replace board 

050 

Short-circuit in temperature probe  Probe failure. 

Replace probe. 

051 

Open temperature probe. 

Bad probe connection, or probe 

failure. 

Check all connections. Replace probe if 

necessary. 

100 

Initial Fill Error. 

Initial fill time took longer than 

expected after powering up. 

Water supply flow rate is too 

low. 

Watch for short potting during brew 

cycle. Investigate cause of low flow 

rate. (Clogged water filter...) 

101 

Error on refill-. 

Tank did not refill within expected 

time. 

Water supply flow rate is too 

low. 

Watch for short potting during brew 

cycle. Investigate cause of low flow 

rate. (Clogged water filter…) 

200 

Heating flatline-Tank is boiling 

Heater is on, temperature is not 

rising/dropping 

High elevation correction.  Bad heaters 

or temperature probe or position 

201 

Heater open, high limit 

thermostat, or Solid State Relay 

(SSR) fault 

Failure of heating element, 

SSR, high limit or low voltage 

Check and replace heating elements, 

SSRs, high limit devices if necessary. 

202 

Heater Shorted or Stuck SSR 

Heater is off and heating 

SSR is stuck “ON” 

Check that ohms range of heater are 

between 10-8

; replace if not.  SSR 

may be stuck in ON mode-replace SSR. 

255 

Keyboard [HID] error 

Usually from longer than 10 sec 

contact. Or faulty reassembly 

after service 

Restart , if still fault:  reload software.  If 

mechanical: replace module 

NO 

BSKT 

 

Insert Brew Basket

 

 

Brew basket must be in place 

 

This is a 

SAFETY FEATURE 

 

Insert brew basket into brewer rails to 

enable brewer 

Summary of Contents for E1231IN-1B123-PM000

Page 1: ...de and Operator Instructions CBS 1231 CBS 1232 Extractor Plus Brewing System FETCO PLUS Commercial Beverage Equipment CBS 1232 CBS 1232 3 0 4 0 Extractor Plus Brewers shown with 2 2 liter Air Pot sold...

Page 2: ...y Weight Filled Weight Shipping Weight Shipping Dimensions CBS 1231 Brewer 27 3 4 in 700 mm 11 3 4 in 300 mm 20 in 520 mm 3 3 gallon 12 4 L 29 lbs 13 2 kg 55 lbs 25 0 kg 41 lbs 18 6 kg 30 x 17 x 22 76...

Page 3: ...erminal Block 1 10 9 13 0 7 7 gal 29 1 L CBS 1231PLUS 3 0 4 0 Lit er Coffee B rewers C E m odels Electrical and Output Specifications Schuko cor d and pl ug 50Hz SKU Voltage Heater C onfiguration Wire...

Page 4: ...rew basket 5 Select a batch hold the corresponding BREW button in for 1 second to start 6 STOP button will illuminate Countdown time will display Selected BREW button will flash to indicate brew is in...

Page 5: ...90 Copy Batch B13 Filter Life F14 Override Lt BBS See Page 12 A91 Copy Batch From F15 Override Rt BBS A92 PASTE To F16 Override Lt BBL F17 Override Rt BBL Left and Right top and middle batches are per...

Page 6: ...30 minutes 2 00 12 00 0 30 Default total brew time is 5 30 minutes A2 30 Prewet Perc 0 0 00 25 0 1 Percentage of total brew volume A2 40 Prewet Delay Brew pause after prewet completes 0 1 00 Min 0 10...

Page 7: ...mperature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 205 212 0 96 100 0 500 152 205 211 0 96 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 2...

Page 8: ...ncrements Notes D1 Heater SSR Test Press button 2 to test button 1 stops test Activates heater Default is 10 sec Toggle OFF or ON Energizes Heater s WARNING Service use only D2 Fill Valve Test Press b...

Page 9: ...47G 61oz 1 05 1 60Liter 0 39 0 55G 50 71 fl ounces 0 05L 0 01G 1 oz Adjusts flow rate E6 LT Bypass valve flow rate 1 30 liters minute 0 36 gallon minute 46 ounces minute 1 10 1 65Liter 0 28 0 42G 37...

Page 10: ...NO Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F10 Restore Defaults NO NO YES Reset to factory When selecting F10 RESTORE...

Page 11: ...r short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank did not refill within expected time Water supply flow rate is too low Watch for short...

Page 12: ...Volume LT Left brew valve flow through volume Gallons Liters Totalized volume through left valve CBS 1232 only G27 A Lt Brew Volume R G28 A Rt Brew Cycles LT Right brew valve operation on off Count T...

Page 13: ...en From SAVE screen Press button 2 to toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT NOTE User Settings will be erased and overwritten to factory default s...

Page 14: ...er such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polish...

Page 15: ...possible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in a position to facilitate filter replacemen...

Page 16: ...nit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or aut...

Page 17: ...1232 4 required for CBS 1231 Legs are sent from factory inside brew basket Attach legs before installing 2 Adjust dispenser locator for either 3 Liter 1 Gallon dispensing Set Dispenser Locator Shown...

Page 18: ...rts Diagram CBS 1231 Drawing 1101 00570 00 Parts CBS 1231 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE 2 1 2 legs Extends to 3 5 8 Part number 1073 00016 00 3 required for CBS 1232 4 requir...

Page 19: ...41 31 11 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 32 1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 33 1 1402 00098 10 HARNESS LOW AMP CBS 1230 UL 34 1 1046 000...

Page 20: ...ts Diagrams CBS 1232 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE Drawing 1101 00571 00 Parts CBS 1232 2 1 2 legs Extends to 3 5 8 Part number 1073 00016 00 3 required for CBS 1232 4 requir...

Page 21: ...023 00355 00 LOCATOR AIRPOT ADAPTER CBS 2230 29 1 1001 00408 00 COVER TOP CBS 2232 42 30 1 1001 00409 00 COVER UPPER BASE CBS 2232 42 31 11 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 32 1...

Page 22: ...UNDERSIZED ZINC PLATED 9 1 1107 00021 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 1 1107 00022 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 1 1107 00020 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 9 1 11...

Page 23: ...OTH LOCKWASHER 8 10 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00022 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 2 1107 00019 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 10 2 1003 00140...

Page 24: ...FITTING STRAIGHT GROMMET 400 10 1 1023 00166 00 FITTING COLD WATER INLET GROMMET DESIGN 11 2 1107 00019 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 11 2 1107 00020 00 HEATER ASSEMBLY IMMERSION 2300W 240...

Page 25: ...02 00113 00 SWITCH REED ASSEMBLY 5 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN ORANGE 6 2 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL interchangeable with 1057 00078 00 6 2 1057 00078 00...

Page 26: ...BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 00192 00 ORANGE PLUG BB HANDLE 1023 00180 00 BLUE PLUG BB HANDLE Stainless Steel Brew Basket Ref Qty Part Number Description B003218B1 Complete Stain...

Page 27: ...Go to fetco com for the latest versions of all information Page 27 User Guide Operator instructions P211e0November 2021 Wiring Diagrams SSR SSR SKU E1231US 1X117 PM001 CBS 1231 Domestic Dual Voltage...

Page 28: ...com for the latest versions of all information Page 28 User Guide Operator instructions P211e0November 2021 S S R Wiring diagram 1401 00190 10 E1231US 1A115 E1231US 1A123 E1231US 1X117 E1231IN 1B130 C...

Page 29: ...com for the latest versions of all information Page 29 User Guide Operator instructions P211e0November 2021 SSR Wiring diagram 1401 00196 10 E1232US 1B223 E1232US 1B230 E1232IN 1B223 E1232IN 1B230 CB...

Page 30: ...End of section notes N...

Reviews: