Fetco E1231IN-1B123-PM000 Users Manual And Operator Instructions Download Page 7

Go to fetco.com for the latest versions of all information         

Page 7

      

User Guide & Operator instructions

   

P211

e0

November 2021

 

B General 

Brewer Operation Control Settings, Adjust Brew Flow Rate

 

POSITION 

Program Items 

Factory set Default 

Programming Range  Increments 

Notes 

B1 

Tank Temp. 

200°F-or-93° C 

NOTE: Equipment is 

Fahrenheit by default 

77° to 97°C 

170°F to 207°F 

0.5°C 

1.0°F 

Chart to correct for 

high altitude below 

B2 

Brew at Temp. 

“YES” 

ON/OFF 

YES/NO 

SEE NOTE BELOW  

B4 

Show Tank 

Temperature 

YES 

YES/NO 

 

To display HW tank 

temperature on screen

 

B5 

Units of Measure 

TEMPERATURE 

° Fahrenheit 

Fahrenheit/Celsius 

C/F 

NOTE

: Overwrites 

user settings 

(see page 9)

 

B6 

Units of Measure 

VOLUME 

Liters 

Gallons/Liters/Ounces 

L/Gal/Oz 

NOTE

: Overwrites 

user settings 

(see page 9)

 

B7 

Customer Name 

Off 

NO or YES 

 

For name on screen 

B7 

Customer Name 

(only if above is “ON)  Scroll with batch keys  A-Z;a-z;0-9 

16 characters total 

B9 

Demo Mode 

DEMO ON/OFF 

 

 

Demonstrates the controls 

for training. Disables all 

components in demo mode

 

B10 

Eco Mode 

On 

ON/OFF 

YES/NO 

If Selected: Lowers hot 

water tank temperature after 

preset time of inactivity 

B11 

Eco Idle Time 

1Hr 

1-6 hours 

1 hour 

Time of inactivity to go into 

ECO Mode 

B12 

Eco Idle Temp 

170°F 

158-176°F 

1 degree 

Temperature that hot water 

tank is lowered to when in 

ECO Mode 

B13 

Filter Life 

OFF 

ON/OFF 

YES/NO 

Water filter life is accessed 

in G-Counters. This is user 

set and will display indicator 

to change water filter 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chart to correct for altitude for boiling point   

in tank water temperature.

 

[ft] 

[m]  Suggested 

Setting[°F] 

Boiling 

point[°F] 

Suggested 

Setting[°C] 

Boiling 

point [°C] 

205 

212.0 

96 

100.0 

500  152 

205

 

211.0 

96

 

99.5 

1000  305 

200

 

210.1 

93

 

98.9 

2000  610 

200

 

208.1 

93

 

97.8 

2500  762 

200

 

207.2 

93

 

97.3 

3000  914 

200

 

206.2 

93

 

96.8 

3500  1067 

197 

205.3 

92 

96.3 

4000  1219 

195 

204.3 

91 

95.7 

4500  1372 

194 

203.4 

90 

95.2 

5000  1524 

194 

202.4 

90 

94.7 

5500  1676 

193 

201.5 

89 

94.2 

6000  1829 

192 

200.6 

89 

93.6 

6500  1981 

191 

199.6 

88 

93.1 

7000  2134 

190 

198.7 

87 

92.6 

7500  2286 

188 

197.8 

86 

92.1 

8000  2438 

187 

196.9 

86 

91.6 

8500  2591 

185 

196.0 

85 

91.1 

BREW AT TEMPERATURE DEFINITIONS 

DEFAULT: BREW AT TEMP:  “ON” 

 

 

(FACTORY  DEFAULT FOR BREWER) 

 

“BREW at TEMP:   

-Batch will not start if tank temperature 

 is below set point. 

-Display will show “HEATING” 

 and hot water tank temperature 

The “BREW START” entry buttons will not 

illuminate until the hot water tank reaches the 

selected temperature.   

 

Controls allow both sides of dual brewer to 

operate if one side has an ongoing brew 

started and the second side brew is selected.   

 

Notifications shown on screen: 

TEXT: 

HEATING

Tank above 87°C/189°F-will 

allow  brew at low temperature.   

Coffee flavor may be affected 

TEXT: 

L. HEAT

Tank above 76°C/169°F-will 

allow brew at low temperature.   

Coffee flavor will be noticeably affected 

 

 

 

Hot water tank not 

at brew temp 

setpoint. 

 

Tank temp

 

 

STOP is not lit 

 

 

BREW START 

buttons not lit. 

and are disabled. 

 

When hot water 

tank temperature is 

at setpoint.  Buttons 

will illuminate and 

“READY” will be 

displayed 

 

                         

vv

vv

vv 

 

HEATING 

160°F 

  

 

  

 

  

 

    

USER SELECTABLE OPTION: BREW AT TEMP:

  

OFF

    

 

(Not recommended) 

 Unit will operate at cold temperature

 

Allows brewing at any temperature above 77°C/170°F 

Below 70°C/170°F The red colored ready lights switch turn off 

STOP 

STOP

 

Summary of Contents for E1231IN-1B123-PM000

Page 1: ...de and Operator Instructions CBS 1231 CBS 1232 Extractor Plus Brewing System FETCO PLUS Commercial Beverage Equipment CBS 1232 CBS 1232 3 0 4 0 Extractor Plus Brewers shown with 2 2 liter Air Pot sold...

Page 2: ...y Weight Filled Weight Shipping Weight Shipping Dimensions CBS 1231 Brewer 27 3 4 in 700 mm 11 3 4 in 300 mm 20 in 520 mm 3 3 gallon 12 4 L 29 lbs 13 2 kg 55 lbs 25 0 kg 41 lbs 18 6 kg 30 x 17 x 22 76...

Page 3: ...erminal Block 1 10 9 13 0 7 7 gal 29 1 L CBS 1231PLUS 3 0 4 0 Lit er Coffee B rewers C E m odels Electrical and Output Specifications Schuko cor d and pl ug 50Hz SKU Voltage Heater C onfiguration Wire...

Page 4: ...rew basket 5 Select a batch hold the corresponding BREW button in for 1 second to start 6 STOP button will illuminate Countdown time will display Selected BREW button will flash to indicate brew is in...

Page 5: ...90 Copy Batch B13 Filter Life F14 Override Lt BBS See Page 12 A91 Copy Batch From F15 Override Rt BBS A92 PASTE To F16 Override Lt BBL F17 Override Rt BBL Left and Right top and middle batches are per...

Page 6: ...30 minutes 2 00 12 00 0 30 Default total brew time is 5 30 minutes A2 30 Prewet Perc 0 0 00 25 0 1 Percentage of total brew volume A2 40 Prewet Delay Brew pause after prewet completes 0 1 00 Min 0 10...

Page 7: ...mperature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 205 212 0 96 100 0 500 152 205 211 0 96 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 2...

Page 8: ...ncrements Notes D1 Heater SSR Test Press button 2 to test button 1 stops test Activates heater Default is 10 sec Toggle OFF or ON Energizes Heater s WARNING Service use only D2 Fill Valve Test Press b...

Page 9: ...47G 61oz 1 05 1 60Liter 0 39 0 55G 50 71 fl ounces 0 05L 0 01G 1 oz Adjusts flow rate E6 LT Bypass valve flow rate 1 30 liters minute 0 36 gallon minute 46 ounces minute 1 10 1 65Liter 0 28 0 42G 37...

Page 10: ...NO Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F10 Restore Defaults NO NO YES Reset to factory When selecting F10 RESTORE...

Page 11: ...r short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank did not refill within expected time Water supply flow rate is too low Watch for short...

Page 12: ...Volume LT Left brew valve flow through volume Gallons Liters Totalized volume through left valve CBS 1232 only G27 A Lt Brew Volume R G28 A Rt Brew Cycles LT Right brew valve operation on off Count T...

Page 13: ...en From SAVE screen Press button 2 to toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT NOTE User Settings will be erased and overwritten to factory default s...

Page 14: ...er such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polish...

Page 15: ...possible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in a position to facilitate filter replacemen...

Page 16: ...nit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or aut...

Page 17: ...1232 4 required for CBS 1231 Legs are sent from factory inside brew basket Attach legs before installing 2 Adjust dispenser locator for either 3 Liter 1 Gallon dispensing Set Dispenser Locator Shown...

Page 18: ...rts Diagram CBS 1231 Drawing 1101 00570 00 Parts CBS 1231 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE 2 1 2 legs Extends to 3 5 8 Part number 1073 00016 00 3 required for CBS 1232 4 requir...

Page 19: ...41 31 11 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 32 1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 33 1 1402 00098 10 HARNESS LOW AMP CBS 1230 UL 34 1 1046 000...

Page 20: ...ts Diagrams CBS 1232 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE Drawing 1101 00571 00 Parts CBS 1232 2 1 2 legs Extends to 3 5 8 Part number 1073 00016 00 3 required for CBS 1232 4 requir...

Page 21: ...023 00355 00 LOCATOR AIRPOT ADAPTER CBS 2230 29 1 1001 00408 00 COVER TOP CBS 2232 42 30 1 1001 00409 00 COVER UPPER BASE CBS 2232 42 31 11 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 32 1...

Page 22: ...UNDERSIZED ZINC PLATED 9 1 1107 00021 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 1 1107 00022 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 1 1107 00020 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 9 1 11...

Page 23: ...OTH LOCKWASHER 8 10 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00022 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 2 1107 00019 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 10 2 1003 00140...

Page 24: ...FITTING STRAIGHT GROMMET 400 10 1 1023 00166 00 FITTING COLD WATER INLET GROMMET DESIGN 11 2 1107 00019 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 11 2 1107 00020 00 HEATER ASSEMBLY IMMERSION 2300W 240...

Page 25: ...02 00113 00 SWITCH REED ASSEMBLY 5 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN ORANGE 6 2 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL interchangeable with 1057 00078 00 6 2 1057 00078 00...

Page 26: ...BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 00192 00 ORANGE PLUG BB HANDLE 1023 00180 00 BLUE PLUG BB HANDLE Stainless Steel Brew Basket Ref Qty Part Number Description B003218B1 Complete Stain...

Page 27: ...Go to fetco com for the latest versions of all information Page 27 User Guide Operator instructions P211e0November 2021 Wiring Diagrams SSR SSR SKU E1231US 1X117 PM001 CBS 1231 Domestic Dual Voltage...

Page 28: ...com for the latest versions of all information Page 28 User Guide Operator instructions P211e0November 2021 S S R Wiring diagram 1401 00190 10 E1231US 1A115 E1231US 1A123 E1231US 1X117 E1231IN 1B130 C...

Page 29: ...com for the latest versions of all information Page 29 User Guide Operator instructions P211e0November 2021 SSR Wiring diagram 1401 00196 10 E1232US 1B223 E1232US 1B230 E1232IN 1B223 E1232IN 1B230 CB...

Page 30: ...End of section notes N...

Reviews: