Festo — YJKP-ST/MT — 2021-11f
Maintenance
27
3.
Port
Description
TCP/UDP
20, 21
FTP
TCP
1024 - 65535
FTP logging
Depending on the FTP server
configuration, ports in this sec-
tion must be enabled.
TCP
4444
Control of servo press via
TCP/IP
TCP
502
Modbus
TCP
44818
EtherNet/IP
TCP
2222
EtherNet/IP
UDP
10002
Festo Field Device Tool
UDP/TCP
445
SMB
TCP
4840, 443
OPC UA
TCP
Tab. 18: Servo press controller ports
Preparation with the FFT
1. Preparation with the FFT: set network parameters of the controller CECC-X-M1-YS.
2. Set network parameters of the motor controller CMMP-AS.
Optional: update firmware and software.
–
Firmware update for controller CECC-X-M1-YS
–
Firmware update for motor controller CMMP-AS
–
Software update for servo press software on the controller CECC-X-M1-YS
Examples with explanations in the application notes from Festo
NOTICE
Increased wear in case of operation with too little stroke.
• Observe the minimum stroke.
• If undercut: minimum stroke of 12.5 mm must be traversed 10 times in every 100 movement cycles.
9
Maintenance
9.1
Safety
WARNING
Risk of injury due to lowering piston rod.
• Before working on the product: Secure the piston rod to prevent it from lowering.