Festo — YJKP-ST/MT — 2021-11f
Installation
17
[X1] power supply CECC-X-M1-YS
WARNING
Risk of injury due to electric shock.
• For the electric power supply, use only PELV circuits that ensure a reliable electric disconnection
from the mains network.
• Observe IEC 60204-1/EN 60204-1.
–
Power supply for device, digital and analogue inputs
–
Resultant current for all supplied ports:
£
750 mA
–
Of which intrinsic current consumption:
£
200 mA
–
Use an external overload protection for the power supply of the device.
Terminal
Connection
Use
X1.1
24
24 V DC
X1.2
0
0 V DC
X1.3
Functional earth
X1.4
not assigned
–
Tab. 9: [X1] power supply connection for device, digital and analogue inputs
1. Connect the power supply to the device.
2. Place the open cable ends in the plug provided in accordance with the table.
3. Insert the plug into the connection [X1] of the controller.
[X5] power supply for digital outputs
–
Power supply for digital outputs.
–
Resultant current for all supplied ports:
£
5 A
Terminal
Connection
Use
X5.1
24
24 V DC
X5.2
0
0 V DC
Tab. 10: [X5] power supply connection for digital outputs
1. Connect the power supply to the device.
2. Place the open cable ends in the plug provided in accordance with the table.
3. Insert the plug into the connection [X5] of the controller.