SFAM
Festo – SFAM – 2017-09c English
9
RECORDER mode
In the RECORDER mode, a manual air consumption measurement can be performed.
2.2
Function range
2.2.1
Switching outputs
Configuration of the switching outputs
Switching output Out A:
This can be done either with the physical input variable flow rate [FLW] or the air consumption
measurement [ConS] derived from it.
Switching output Out B:
can only be used with the physical input variable flow rate.
Switching outputs Out A/Out B can be configured according to the setting range in the technical data
è
Tab. 13.
For the switching output Out A and Out B, the switching function threshold value or window comparator
can be selected independently of one another. Each switching output can have the switching element
function N/C contact (NC – normally closed) or N/O contact (NO – normally open) separately allocated
toit
è
Tab. 3.
Switching points [SP] and hysteresis [HY] can be set corresponding to the setting ranges in the
technical data table
è
Tab. 13.
Switching point and hysteresis with flow rate measurement for Out A/Out B
Threshold value comparator
Window comparator
Switching element function NO (normally open contact)
q
1
0
HY
OUT
SP
[l/min.]
HY
HY
q
1
0
OUT
SP Lo
SP Hi
[l/min.]
Switching element function NC (normally closed contact)
q
1
0
SP
HY
OUT
[l/min.]
q
1
0
OUT
SP Lo
SP Hi
HY
HY
[l/min.]
Tab. 3
Switching point SP and hysteresis Hy setting