Carry out a test run with various flow rates to ascertain whether the SFAM switches as desired
(switching points and hysteresis).
b) Set consumption monitoring
Note
Air consumption measurement [ConS] can be activated for switching output Out A.
The SFAM is in the EDIT mode and [Out A] flashes
è
Chapter Start EDIT mode.
1. Press the Edit button to confirm the selection.
[FLW] or [ConS] flashes.
2. Select the air consumption measurement [ConS] with the A/B pushbuttons.
3. Press the Edit button to confirm the selection.
[CI] flashes.
4. Set the value for the consumption impulse (CI) with the A/B pushbuttons.
5. Press the EDIT button to confirm the set value.
[NO] or [NC] flashes.
6. Select the switching element function (NO/NC) with the A/B pushbuttons.
7. Press the EDIT button to confirm the set value.
The SFAM is in RUN mode
Carry out a test run with various flow rates to ascertain whether the SFAM switches as desired.
5.5.3
Set special menu [SPEC]
This is how you reach the special menu:
The SFAM is in the EDIT mode and [Out A] flashes,
è
Chapter Start EDIT mode.
1. Press the A or B pushbutton until the menu (SPEC) is selected.
[SPEC] flashes.
2. Press the Edit button to confirm the selection.
[Option] flashes, the standard conditions (OFF, 1 or 2) can be set.
Set standard conditions [Option]
3. Select the desired setting (OFF, 1 or 2) with the A/B pushbuttons.
4. Press the Edit button to confirm the selection.
[FLW] is displayed and the currently chosen value flashes.
The unit for the flow rate (l/min or scfm) can be set.
Setting the physical unit for the flow rate [FLW]
5. Select the desired setting (l/min or scfm) with the A/B pushbuttons.
6. Press the Edit button to confirm the selection.
[AnA.F] and the currently set value are displayed. The analogue filter can be set.
Note
The configured physical unit is shown in RUN mode in the display at the bottom right.