In Show mode, depending on whether the A or B pushbutton is pressed, the current settings for the
switching outputs Out A or Out B will be shown.
The SFAM must be in RUN mode.
When air consumption measurement is activated, the INFO mode enables rapid changeover of the
input variables flow rate and air consumption in the display by pressing the A or B pushbutton.
Note
If there are errors, pressing the A pushbutton/B pushbutton first displays
corresponding error numbers.
Repeated pressing of the A pushbutton/B pushbutton displays the settings of the respective
switching output one after another.
At the end of SHOW mode, the min value [F.Lo] and max value [F.Hi] are displayed. If no further
buttons are pressed, the display remains constant (no timeout). The min and/or max display is
thereby signaled by the flashing of segment 1 or segment 10 in the bar graph
è
Tab. 9.
The min/max values can be reset by pressing the Edit button.
When all settings have been displayed, the SFAM goes back into RUN mode when the
Apushbutton/B pushbutton are pressed again and displays the current measurement value
forthecorresponding output.