Festo — SFAB-...-PNLK — 2022-08
Technical data
47
SFAB
-10U
-50U
-200U
-600U
-1000U
Communication interface
IO-Link, Revision ID
V1.1
IO-Link, device profile
–
Smart Sensor - SSP 4.1.2
–
Firmware update
–
Identification and diagnostics
–
Function measurement data, standard resolution
–
Function multiple switching signal
–
Function teach single value
–
Function extended identification
–
Function locator
–
Function Product URI
IO-Link, transmission rate
COM3
IO-Link, SIO mode support
Yes
IO-Link, port type
Class A
IO-Link, process data
length output
[bit]
0
IO-Link, input process
data length
[bit]
64
IO-Link, process data content IN
–
Flow rate measurement 16 bit MDC
–
Flow rate monitoring 2 bit SSC
–
Measured temperature value 16 bit MDC
–
Temperature monitoring 2 bit SSC
–
Volume pulse/mass pulse 1 bit SSC
IO-Link, service data content IN
Volume reading/mass reading 32 bit
IO-Link, minimum cycle
time
[ms]
1.2
IO-Link, data memory
required
[Kbyte]
0.5
Electronics
Operating voltage range
[V DC]
15 … 30
No-load current (at 24 V
DC and 100% flow)
[mA]
90
Max. ready-state delay
[ms]
500
Reverse polarity protec-
tion
For all electrical connections