background image

SFAB-...-PNLK

Flow sensor

Operating instruc-

tion

8172190

2022-08

[8172192]

Summary of Contents for SFAB-PNLK Series

Page 1: ...SFAB PNLK Flow sensor Operating instruc tion 8172190 2022 08 8172192...

Page 2: ...Translation of the original instructions IO Link is a registered trademark of its respective trademark holder in certain countries...

Page 3: ...point synchronisation 14 5 Mounting 14 5 1 Mounting the sensor on the H rail 15 5 2 Mounting the sensor with wall mounting 15 5 3 Mounting the sensor on the plate 16 5 4 Rotating the display 16 6 Inst...

Page 4: ...mmands 28 8 5 Smart sensor profile parameters 29 8 6 Device specific parameters 34 8 7 IO Link teach in 38 8 8 Block parameterisation 39 8 9 Process data IN 41 8 10 Diagnostics IO Link 41 9 Operation...

Page 5: ...ifications 13 Technical data The product may generate high frequency interference which may require interference suppression measures in residential areas 2 2 Intended use The flow sensor monitors the...

Page 6: ...2 3 4 5 6 7 8 9 Fig 1 Control elements and connection elements 1 Pneumatic connection 1 2 Display 3 Pushbutton B 4 Edit key 5 Pushbutton A 6 Plug for the electrical connection M12 7 Pneumatic connect...

Page 7: ...eaning Output display OutA Switching output OutA selected flashes when IO Link is active OutA Switching output OutA set OutC Volume pulse OutC selected flashes when IO Link is active OutC Volume pulse...

Page 8: ...utA OutB OutC Edit Flow Edit menu for the switching outputs OFF Fctn Switching function deactivated _I Fctn Threshold value comparator _I I_ Fctn Window comparator _ Fctn 2 point threshold value compa...

Page 9: ...time after which the display background lighting is switched off PNP bin Out Switchover of the switching outputs between PNP and NPN FLOW bin Pin4 Switchover of the switching signal at pin 4 between...

Page 10: ...volume or mass pulse VMP REC volume or mass recorder VMR tEMP temperature t FLOW OutA FLOW OutB PULS OutC binary q SSC1 1 binary q SSC1 2 binary VMP SSC1 3 FLOW analogue q MDC1 analogue t MDC2 tEMP P...

Page 11: ...n N C normally closed Switching function 2 switching points SP Lo SP Hi TEACH mode 1 2 teach points TP1 TP2 TP1 SP Lo TP2 SP Hi 1 SP Lo smaller value SP Hi larger value independent of the teach sequen...

Page 12: ...value for the volume or the mass is set in the accumulated volume measurement or mass measurement If the configured threshold value is reached the SFAB outputs a switching pulse at the switching outpu...

Page 13: ...can be scaled to the partial range The analogue output can also be scaled in the negative range up to 100 FS Scale 0 100 default Scale 20 80 Fig 5 Example scaling of the analogue signal at the curren...

Page 14: ...the physical standard conditions in accordance with DIN 1343 If a standard other than DIN 1343 is selected the specified measurement range 100 FS changes in value by the factor specified in Tab 9 Stan...

Page 15: ...to the DIN rail 2 Press the sensor in the direction of the arrow The sensor snaps into place 5 2 Mounting the sensor with wall mounting Fig 7 Wall mounting 1 Fasten the adapter plate with 2 screws M3...

Page 16: ...splay The display can be rotated in 90 steps The turning range is limited to approx 270 by a stop Fig 9 Rotate the display 6 Installation 6 1 Installation pneumatic The flow rate is supplied at connec...

Page 17: ...nut at the plug connector max 0 3 Nm Plugs Pin Wire colour1 Allocation M12 5 pin 1 Brown BN Operating voltage 24 V DC 2 White WH Electrical output 2 OutB or analogue 3 Blue BU Operating voltage 0 V 4...

Page 18: ...nt the sensor is ready for operation and is in RUN mode Switching output OutA or volume output 1 Press the A key twice in rapid succession The first parameter set Pin4 bin is displayed 2 Press the A p...

Page 19: ...022 08 Commissioning 19 Button A or Button B Double click button A or button B Button Edit or or or Measured value indicator Run mode Measured value indicator Run mode see to or or Fig 11 Menu structu...

Page 20: ...Default Fig 12 EDIT mode menu structure 7 3 1 Starting EDIT Mode Requirement the sensor is ready for operation and is in RUN mode 1 Press the Edit key The EDIT mode is active OutA and Edit are display...

Page 21: ...ettings Requirement EDIT mode is active 1 Select the Spec with the A or B key Spec is displayed 2 Press the Edit key Filt MSEC flashes 3 Set the parameter with the A or B key 4 Press the Edit key The...

Page 22: ...must not be blocked via IO Link Master Sensor Power Suppply Device Sensor Fig 13 Replicate pin allocation parameters 1 Select the SPEC special menu from the device settings on the master sensor 2 Pres...

Page 23: ...ss the Edit button If OK appears the zero point synchronisation was successful FAIL appears the zero point synchronisation was not successful Check requirements If Z AdJ OFF is set for a later time th...

Page 24: ...ey 4 Press the Edit key t IN flashes The measured value will then be applied as teach point TP1 5 Generate the flow rate for TP2 6 Press the A key and the Edit key The measured value will then be appl...

Page 25: ...nction Product URI Transmission rate COM3 SIO Mode support Yes Port type class A Process data output length 0 bit Process data input length 64 bit Process data content IN Flow measurement value 16 bit...

Page 26: ...r Code e g SFAB 10U HQ6 PNLK PNVBA M12 Max 64 0x0013 19 0x00 Product ID E g 563795 SFAB 10 0x0014 20 0x00 Product Text Flow sensor 11 0x0015 21 0x00 Serial Number Product Key e g MW3N10KCP3X 11 0x0016...

Page 27: ...gerT16 0x0024 36 0x00 Device Status 0 Device is operating properly 2 Out of Specification 4 Failure UInter gerT8 0x0025 37 0x00 Detailed Device Status Octet1 event identi fier Octet2 3 event code 8 10...

Page 28: ...t Device warm start 129 0x81 Application Reset Reset the technology specific application 130 0x82 Restore factory settings Sets the factory settings opera tive again 131 0x83 Back to box Restore param...

Page 29: ...Class ID 0x8102 Product URI 0x000E 14 0x00 R PD Input Descriptor 0x03 0x10 0x30 0x03 0x08 0x28 0x01 0x03 0x20 0x03 0x10 0x10 0x03 0x08 0x08 0x01 0x02 0x00 ArrayT of Octet StringT3 0x01 Flow value MDC...

Page 30: ...flagTP2 for SP2 SSC1 1 flow rate monitoring OutA 0x003C 60 0x00 R W SSC1 1Param Combined value RecordT 64 bit 0x01 Setpoint SP1 SP SP Lo SP Hi SFAB 10 0 6000 SFAB 50 0 3000 SFAB 200 0 12000 SFAB 600 0...

Page 31: ...IntegerT32 0x02 Setpoint SP2 SP SP Lo SP Hi SFAB 10 0 6000 SFAB 50 0 3000 SFAB 200 0 12000 SFAB 600 0 3600 SFAB 1000 0 6000 0x003F 63 0x00 R W SSC1 2Config Combined value RecordT 48 bit 0x01 Switchpo...

Page 32: ...ted 1 Single point mode _ 2 Window mode _ _ 3 Two point mode _ 0x03 Hysteresis HY 0 900 IntegerT32 SSC2 2 temperature monitoring 0x400E 16398 0x00 R W SSC2 2Param Combined value RecordT 64 bit 0x01 Se...

Page 33: ...SFAB 10 6000 SFAB 50 3000 SFAB 200 12000 SFAB 600 3600 SFAB 1000 6000 0x03 Unit code 1349 m h UInte gerT16 0x04 Scale SFAB 10 4 10 4 SFAB 50 3 10 3 SFAB 200 3 10 3 SFAB 600 2 10 2 SFAB 1000 2 10 2 Int...

Page 34: ...ypically 1 200000000 Scale m3 SFAB 10 x 0 00001 SFAB 50 x 0 0001 SFAB 200 x 0 001 SFAB 600 x 0 001 SFAB 1000 x 0 001 UInte gerT32 0x0147 327 0x00 Volume mass pulse switch point logic PULS logic 0 High...

Page 35: ...lt 0 Filter off 1 2 ms 2 4 ms 3 8 ms 4 16 ms 5 32 ms 6 64 ms 7 128 ms 8 256 ms 9 512 ms 10 1024 ms 11 2048 ms 0x0184 388 0x00 User zero adjustment on off Z Adj 0 off 1 on 0x01A7 423 0x00 R Volume mass...

Page 36: ...selection 0 Flow monitoring SSC1 1 OutA FLOW bin 1 Volume mass pulse SSC1 3 OutC VOL bin 0x01E8 488 0x00 Backlight duration Eco 0 always on 1 5 s 2 10 s 3 20 s 4 40 s 5 80 s 6 160 s 7 320 s 8 640 s 0...

Page 37: ...0 0001 SFAB 200 x 0 001 SFAB 600 x 0 001 SFAB 1000 x 0 001 UInte gerT32 0x2084 8324 0x00 Temperture value MDC2 t 215 215 1 IntegerT16 0x2085 8325 0x00 value of volume mass recorder REC Typically 1 20...

Page 38: ...c and hysteresis The switching mode must not be deactivated OFF 2 Set the teach channel to the desired switching channel parameter 0x003A Single value teach in according to IO Link specification With...

Page 39: ...ock parameterisation Block parameterisation is used to prevent individual parameter values from being incompatible with the values stored in the device All parameters transmitted as a block will be si...

Page 40: ...nitoring SSC2 1 Index Subindex Name 0x400E 16398 0x01 Setpoint SP1 0x02 Setpoint SP2 0x400F 16399 0x02 Switchpoint mode 0x03 Hysteresis Tab 23 Block parameterisation for temperature monitoring SSC2 2...

Page 41: ...le no used SSC2 2 SSC2 1 Data content 16 bit tempera ture t 8 bit decimal exponent Index 0x00028 0x0028 SubIndex 0x0B 0x0C 0x0E 0x0D Data type Integer16 Integer8 Boolean Tab 26 Process data IN MDC2 te...

Page 42: ...rates note the following Make sure that the volumetric flow rates to be compared refer to the same standard conditions e g operating volumetric flow rate amount supplied by a compressor measured valu...

Page 43: ...e Er20 t Hi Temperature error in IO Link driver Eliminate short circuit or overload Measured value Er21 SHRt Overload or short circuit at the OutA OutC switching output Eliminate short circuit Measure...

Page 44: ...metric flow rate Mass flow rate Temperature Volume Flow direction Unidirectional P1 P2 Measurement principle Thermal Measurement method Heat loss Warm up time min 5 Flow measuring range compressed air...

Page 45: ...or flow rate Accuracy of compressed air zero point3 FS 0 3 Accuracy of zero point argon CO2 4 FS 2 Accuracy of spread3 FS 3 Repetition accuracy of zero point FS 0 2 Repetition accuracy of spread FS 0...

Page 46: ...on time ms 10 at Filt OFF Max switch off time ms 10 at Filt OFF Pull down resistor PNP integrated Pull up resistor NPN integrated Inductive protective circuit Present Analogue output Characteristic fl...

Page 47: ...upport Yes IO Link port type Class A IO Link process data length output bit 0 IO Link input process data length bit 64 IO Link process data content IN Flow rate measurement 16 bit MDC Flow rate monito...

Page 48: ...ree of protection in accordance with EN 60 529 IP65 Standard nominal flow rate according to ISO6358 ISO 8778 l min 43 5 163 760 1630 1630 1 Accuracy under nominal conditions 6 bar 23 C and horizontal...

Page 49: ...ditions is the result of adding the spread and zero point errors The actual flow rate is in the range of 600 18 3 l min 600 21 l min Display error under deviating nominal conditions e g 8 bar 40 C Tem...

Page 50: ...2022 all rights reserved to Festo SE Co KG Copyright Festo SE Co KG 73734 Esslingen Ruiter Stra e 82 Deutschland Phone 49 711 347 0 Internet www festo com...

Reviews: