B. Supplementary information
B-33
Festo P.BE-MTR-DCI-IO-EN en 1209d
Homing_Method
CI access
6098h
00h
Var
uint8
rw
Description
Defines the method with which the drive carries out homing run.
The MTR-DCI supports the following modes:
Values
Function
-17 (0xEF)
Search for stop in negative direction
-18 (0xEE)
Search for stop in positive direction
23 (0x17)
Search for reference switch in positive direction
27 (0x1B)
Search for reference switch in negative direction (default)
Homing_Velocities
CI access
6099h
01h...02h
Array
uint32
rw
Description
Speeds during homing run in inc/s.
The following applies for firmware V1.19: The value must be divisible by 200,
otherwise it will be rounded to the next permitted value.
Search REF 6099h
01h
int32
rw
Speed when searching for the reference point REF
MTR-DCI-...
Value range (depends on gear)
...-32...-G7 (G14)
200...33000 DMES-18:
Z
0...6.1 (3) mm/s
...-42...-G7 (G14)
200...50000 DMES-25:
Z
0...9.3 (4.6) mm/s
...-52...-G7 (G14)
200...50000 DMES-40:
Z
0...14.8 (7.3) mm/s
...-62...-G7 (G14) (G22)
200...56600 DMES-63:
Z
0...25.2 (12.4) (7.7) mm/s
Default:
...-32...
27000 (0x006978) DMES-18:
Z
5 (2.5) mm/s
...-42...
22400 (0x005780) DMES-25:
Z
4.2 (2) mm/s
...-52...
16800 (0x0041A0) DMES-40:
Z
5 (2.5) mm/s
...-62...
16800 (0x005780) DMES-63:
Z
7.5 (3.7) (2.3) mm/s
Search AZ 6099h
02h
int32
rw
Speed of travel to the axis zero point AZ
Value range: see Object 6099/01h
Summary of Contents for MTR-DCI-...IO Series
Page 1: ...Description MTR DCI IO Description 539616 en 1209d 763197 Motor unit MTR DCI ...
Page 4: ...Contents and general instructions II Festo P BE MTR DCI IO EN en 1209d ...
Page 8: ...Contents and general instructions VI Festo P BE MTR DCI IO EN en 1209d ...
Page 19: ...System summary 1 1 Festo P BE MTR DCI IO EN en 1209d Chapter 1 System summary ...
Page 35: ...Mounting 2 1 Festo P BE MTR DCI IO EN en 1209d Chapter 2 Mounting ...
Page 43: ...Installation 3 1 Festo P BE MTR DCI IO EN en 1209d Chapter 3 Installation ...
Page 58: ...3 Installation 3 16 Festo P BE MTR DCI IO EN en 1209d ...
Page 79: ...Commissioning 5 1 Festo P BE MTR DCI IO EN en 1209d Chapter 5 Commissioning ...
Page 120: ...6 Operating maintenance and diagnosis 6 12 Festo P BE MTR DCI IO EN en 1209d ...
Page 121: ...Technical appendix A 1 Festo P BE MTR DCI IO EN en 1209d Appendix A Technical appendix ...
Page 175: ...Index C 1 Festo P BE MTR DCI IO EN en 1209d Appendix C Index ...