![Festo MPS PA Operating Instructions Manual Download Page 61](http://html1.mh-extra.com/html/festo/mps-pa/mps-pa_operating-instructions-manual_2283255061.webp)
Bottling Learning System
Maintenance and troubleshooting
© Festo Didactic
696690
61
12.4
Error in the electrical system
The following table shows errors that can be simulated through use of the electrical components or that can
occur due to incorrect operation.
Location
Error /
Disturbance variable /
Danger potential
What is the effect of the
error, disturbance
variable, or danger?
What causes errors?
How can I detect and
prevent errors?
Electrical faults
19" frame
back/underside
Power supply faulty
No electrical function
Unplug the IEC power
cable or remove the
micro fuse
Observe the light at the
power supply switch or
measure the voltage
I/O terminal
No switching function
24 VDC outputs do not
switch, sensors are not
displayed by LEDs
Unplug the SysLink cable
from the I/O terminal
Visual inspection
Pump PL1
Flow rate too low
Flow rate too low,
increased filling time
On the motor controller,
exchange ports 1 and 2
of the pump
Display of flow rate at
only ~ 2 l / min
Pump PL1
Flow rate too low
Flow rate too low,
increased filling time
Turn the adjusting screw
on the motor controller
counterclockwise with a
small screwdriver
Select the container.
SysLink I/O terminal
Signal statuses faulty
Switching signals are not
displayed or are
displayed incorrectly
Slide switch is in
position NPN instead of
PNP
Visual inspection
with data sheet, observe
representation
12.5
Mechanical faults
The following table shows errors that can be influenced mechanically or can occur as a result of incorrect
operation.
Location
Error /
Disturbance variable /
Danger potential
What is the effect of the
error, disturbance
variable, or danger?
What causes errors?
How can I detect and
prevent errors?
Mechanical faults
Lower tank VE1
Filling level via
capacitive sensors
Incorrect or absent
signal display
Turn the sensor or adjust
the mounting bracket
along the profile
Visual inspection of I/O
check