Bottling Learning System
Commissioning
© Festo Didactic
696690
55
11.6
Actuation with EasyPort 19 “
Cable connections between station and EasyPort 19 "
The cable connections are for one MPS PA station connected to EasyPort 19 ”described and illustrated:
•
Connect digital I / Os of port 1 of the EasyPort and the I / O terminal (4) XD1 of the station with I / O
data cable SysLink (6) or check the connection.
•
Connect digital I / Os of port 2 of EasyPort and control panel (9) with I / O data cable SysLink (4) or
check the connection.
•
Connect analog I/Os of port 3 of the EasyPort and analog terminal XD3 (5) of the station
with analog I/O data cable (7) or check the connection.
•
Connect EasyPort for power supply and power supply unit with laboratory cables
(7 - 4 mm safety plug red = + / blue = -) or check the connection.
•
Connect your PC or operator unit to EasyPort using a network cable (not shown) or check the
connection.
Figure 37: Cable connection MPS PA Station – EasyPort 19
″
Legend
1 I/O connection board MPS-PA station
2 Power supply unit 24 V DC, 4.5 A
3 EasyPort 19 ”
4 I/O terminal SysLink
5 Analog terminal
6 SysLink I/O data cable, parallel (034031)
7 Analog cable, 15-pin, parallel (529141)
8 Laboratory cable with safety laboratory sockets
(red/blue)
9 Control panel with I/O data cable SysLink, parallel
(034031)
Summary of Contents for MPS PA
Page 6: ...Bottling Learning System 6 Festo Didactic 696690...
Page 65: ......
Page 66: ......
Page 67: ......