Work and safety instructions
Bottling Learning System
20
© Festo Didactic
696690
6.2.3
Control panel
I/O
Reference
designation
Designation
Terminal
SysLink
Pin
SysLink
Wire color
I0
-SF1
START button
13
Gray-pink
I1
-SF2
STOP button (NC contact)
14
Red-blue
I2
-SF3
AUTO/MAN key switch
15
White-green
I3
-SF4
RESET button
16
Brown-green
I4
I4
Communication input I4
17
White-
yellow
I5
I5
EMERGENCY STOP (NC contact)
18
Brown-
yellow
I6
I6
Communication input I6, successor station process ready
19
White-gray
I7
I7
Communication input I7, successor station ready for bottle
20
Gray-brown
Q0
-PF1
Indicator light START
1
White
Q1
-PF2
Indicator light RESET¶
2
Brown
Q2
-PF3
Indicator light function Q1
3
Green
Q3
-PF4
Indicator light function Q2
4
Yellow
Q4
Q4
Communication output Q4, station ready for process
5
Gray
Q5
Q5
Communication output Q5, station ready for bottle
6
Pink
Q6
Q6
Communication output Q6
7
Blue
Q7
Q7
Communication output Q7
8
Red
24 V A
24 V power supply for outputs
9+10
Black
24 V B
24 V power supply for inputs
21+22
White-pink
GND A
0 V power supply for outputs
11
Brown-pink
GND A
0 V power supply for outputs
12
Purple
GND B
0 V power supply for inputs
23+24
White-blue
Note
Communication input I5 is used as an EMERGENCY-STOP signal input in PLC EduTrainers.
The inputs and outputs of the control panel are located on the second byte of the EduTrainer.