4. Commissioning
4−21
Festo P.BE−MPA−EN en 0802c
4.7.2
Operating states of the pneumatic system
The following conditions should be fulfilled, in order that the
desired pneumatic operating states listed below can be
achieved:
Desired pneum.
operating status
Requirement
Comment
Free of leakage
Tubing connected with care
Regulated pilot air supply
Fast reaction
Sufficient pressure supply by means
of pressure supply modules
Exhaust the MPA−S valve terminal via
all the exhaust plates or via the large
surface−mounted silencer
Faultless
Non−return valves in common
exhaust line
This applies when several systems
with centrally ducted exhaust are
used
Two or more
pressure zones
Limiting the pressure zones by
means of isolating seals with
blocked channels
Appropriate number of pneumatic
supply plates for the various
pressure zones.
Subsequent conversion possible
(seechapter 5)
Vacuum or low−
pressure operation
Externally supplied regulated pilot
air (3
Ū
8 bar)
Vacuum/low−pressure operation not
with 3/2−way valves
EMERGENCY STOP of
pressure zones
Guaranteeing the controller function
for the pilot air despite the complete
supply being switched off
The controller regulates the pilot air
supply to all the valve plates on an
MPA−S valve terminal
Slow start−up after
EMERGENCY STOP
If there are control signals, the pilot
air must have a pressure of 3
Ū
8 bar
immediately after being switched on
Tab.4/12:
Pneumatic operating states
Summary of Contents for MPA-ASI Series
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE MPA EN en 0802c...
Page 8: ...Contents and general instructions VI Festo P BE MPA EN en 0802c...
Page 18: ...Contents and general instructions XVI Festo P BE MPA EN en 0802c...
Page 19: ...Summary of components 1 1 Festo P BE MPA EN en 0802c Chapter 1...
Page 55: ...Fitting 2 1 Festo P BE MPA EN en 0802c Chapter 2...
Page 71: ...Installation 3 1 Festo P BE MPA EN en 0802c Chapter 3...
Page 106: ...3 Installation 3 36 Festo P BE MPA EN en 0802c...
Page 107: ...Commissioning 4 1 Festo P BE MPA EN en 0802c Chapter 4...
Page 128: ...4 Commissioning 4 22 Festo P BE MPA EN en 0802c...
Page 129: ...Maintenance and conversion 5 1 Festo P BE MPA EN en 0802c Chapter 5...
Page 169: ...Technical appendix A 1 Festo P BE MPA EN en 0802c Appendix A...
Page 186: ...A Technical appendix A 18 Festo P BE MPA EN en 0802c...
Page 187: ...Supplementary component summary B 1 Festo P BE MPA EN en 0802c Appendix B...
Page 201: ...Index C 1 Festo P BE MPA EN en 0802c Appendix C...
Page 202: ...C Index C 2 Festo P BE MPA EN en 0802c Contents C Index C 1...