5
Operation and diagnostics
Festo – GDCP-EXPT-KM-KOMP-EN – 1204a – English
29
5
Operation and diagnostics
Caution
Crushing of body parts and damage to the system.
Unintended starting can trigger unexpected movements.
•
Before any conversion or maintenance work or inspections of the system, ensure
that the system is safely brought to a standstill and is locked off to prevent restart-
ing.
Detached parts could cause unexpected movements or fall down.
•
Secure the parts so that they cannot move unexpectedly or bring them into a secure
end position.
Note
Maintenance work should only be conducted by properly trained personnel in accord-
ance with these instructions.
5.1
Maintenance and care
Lubricating ball joints
•
Lubricate the ball joints (
2
Fig. 6.4) every 2000 operating hours with lubricant LUB-KC1 (tube
included). Removal is described in (
Chapter 6.1.5).
Lubricating toothed belt axes
•
Lubricate the toothed belt axes as follows:
Size
45/70
Toothed belt axis
DGE-25-...-ZR-RF
Maintenance task
Oiling the roller guide
Lubrication interval
in operating hours
[h]
6000
Lubricant (oil)
Constant OY 390 (from Klüber)
Lubricating point
Tab. 5.1