Using PELV circuits guarantees protection against electric shock (protection
against direct and indirect contact) in compliance with IEC/DIN EN 60204-1
(electrical equipment on machines, general requirements).
Note
Improper handling can cause damage to the electronic modules.
S
Turn off the supply voltages before performing any assembly and installation
work.
S
Only turn on electric power supplies when the product is fully assembled and
all installation work is complete.
S
Electronics modules contain electrostatically sensitive devices. Therefore, do
not touch any components. Observe the handling specifications for electro-
statically sensitive devices.
Setting the PROFIsafe address
To allow communication via PROFIsafe, the correct PROFIsafe address must be set
on the cut-off module with a 10 position DIL switch with binary coding. PROFIsafe
addresses in the range 1 to 1023 are permissible. The DIL switch is located dir-
ectly on the electronics module and can be adjusted when the connection block is
dismantled. The following figure shows the DIL switch with addressing examples.
10 position DIL switch
Addressing example
1
2
4
8
16
32
64
128
256
512
2 + 64 + 512 = 578
Fig. 5: 10 position DIL switch on output module CPX-FVDA-P