Commissioning
48
© Festo Didactic
8154245 en
D-Sub-interface for analogue signals (option
–
not available at all application modules)
The CP application module produces a analogue output signal. These is put on the analogue terminal (4)
and must be connected with the analogue inputs of the basic module:
•
Connect the analogue terminal (4) of the CP application module with the D-Sub-interface for analogue
signals (6) on the rear board of the basic module CP Lab Conveyor. Therefore use the provided
connecting cable (1) with standard D-Sub plugs: 15-pin, two-rowed.
Electrical connections / illustration similar
Position
Description
1
connecting cable with15-pin standard D-Sub-plugs
2
basic module CP Lab Conveyor: control or decentralized periphery
3
CP application module: I/O terminal (+BG-XD1)
4
CP application module: analogue terminal (+BG-XD2A)
5
connecting cable with a SysLink-plug (SysLink-cable)
6
basic module CP Lab Conveyor: board at the back (+G1-XZ2)
Summary of Contents for CP-AM-MEAS