4.4
Identification
The boiler can be identified from the:
- Document envelope (1)
This is applied to the door, and contains:
TECHNICAL MANUAL
WARRANTY CERTIFICATE
LABELS WITH BARCODE
RATING LABEL
CONSTRUCTION CERTIFICATE
(certifying that the water pressure tests have been passed)
- Rating label (2)
This describes the technical specifications and the performance of the appliance.
It is included in the document envelope and MUST BE APPLIED by the installer,
when installation is complete, to the top front part of one of the side panels of the casing,
in a visible position. If the label is lost, contact the Ferroli Technical Service for a duplicate.
Tampering with or the removal or absence of rating labels or other means enabling the unit
to be identified causes problems during installation and maintenance.
5. INSTALLATION
5.1 Packaging
The
TP3 LN
boilers are supplied complete with the door and smokebox fitted and insulation on the body, while the casing is contained in a se-
parate cardboard box (Fig. 2). The instrument panel (accessory to be ordered separately) is supplied in a cardboard box and positioned inside
the combustion chamber.
5.2 Handling
The TP3 LN boilers are fitted with eyebolts for lifting.
Make sure the hoisting equipment used is suitable for the weight being
lifted. Before positioning the boiler, remove the wooden base support by
unscrewing the fastening screws (Fig. 4).
fig. 3
1
2
0694
Modello
Model
230V - ~50 Hz
Elektrisk forsyning
Alimentazione elettrica
Electrical Input
Alimantation éléctrique
Alimentaciòn eléctrìca
Stromspannung
Stroomspanning
Alimentacao elèctrica
Ingaende spanning
Potenza termica Nominale
l
co
d.
31
35
04
91
Nominal Power Output
Portata Termica Nominale
Nominal Power Input
kW
kW
Max Pressure Heating
bar
Max Temp. Riscaldamento
Max Temp Heating
°C
Max Press. Riscaldamento
No. Matricola
Construction No.
Konstruktions-nr.
Herstellnr.
Nennwarmeleistung
Nominal warmtevermogen
Nennheizwert
Nominaal verwarmingsvermogen
Max. Wasserdruck
Max. waterdruk
Max. Kesseltemperatur
Max. Ketelstemperatuur
Fabrikaatnr.
No.de fabrication
No de construccao
Valmistusnumero
No.de fabricacion
Dèbito tèrmico nominal
Dèbit thermique nominal
Nominell varmetillforsel
Caudal tèrmico nominal
Nominel termisk forsyning
Puissance nominal
Potencia Nominal
Potencia Nominal
Nomineel effekt
Nominel Kraft
Pression maxi Chauffage
Pressao màx. de caldeira
Presiòn màx. de Calefacciòn
Max tryck
Varmeanlaegets maks.-tryk
Temperature maxi Chauffage
Temperatura màx. de caldeira
Temper.màx.de Calefacciòn
Max varmartemperatur
Varmeanlaegets maks.-temperatur
H O
Codice Pin
Code
t.max safety 114°C
bar
Pressione prova idraul./Data
Hidraulic test pressure/Date
Pression d'épreuve hydraulique/Date
Prueba presiòn hidràulica/Fecha
Druck wasserdruckprÜfung/Datum
Vandtrykprøve/Dato
Waterdrukproef/Datum
PressÃo do teste hidràulico/Data
Hydrauliskt testtryck/Datum
VIA RITONDA 78/A - 37047 SAN BONIFACIO - VR - ITALY
Заводской
номер
Теплопроизводительность
Полезная
Тепловаямошность
Макс
.
рабочее давление
Макс
.
рабочее температура
Обьем котловой воды
Опрессовочное давление
/
Дата
Электропитание
Код
Модель
2
1
fig. 4
Summary of Contents for TP3 LN 1060
Page 64: ...64 RU TP3 LN cod 3545458 0 10 2019 5 3 5 TP3 LN 1300 90 R x Q 500 600 600 1000 X 1000 5...
Page 70: ...70 RU TP3 LN cod 3545458 0 10 2019 6 6 1 5 5 5 6 2 160 6 3 7 O C BAH E 7 1 7 2...
Page 71: ...71 RU TP3 LN cod 3545458 0 10 2019 7 3 7 4 1 2 3 4 5 6 7 5 1 13 14 5 4 6 1 3 2 5 4 6 1 3 2...
Page 72: ...72 RU TP3 LN cod 3545458 0 10 2019 30 2 3 7 6 7 7...
Page 73: ......
Page 74: ......
Page 75: ......