BLUEHELIX TECH RRT 24 H
155
EN
cod. 3541C661 - Rev. 00 - 10/2018
When the boiler is turned off, the circuit board is still
powered. Domestic hot water and heating are disa-
bled. The frost protection system remains activated.
To relight the boiler, press the
winter/summer/off
button
(detail 7 - fig. 1) twice.
fig. 9
The boiler will be immediately ready in Winter and DHW mode.
B
The frost protection system does not work when the power and/or gas to the unit are turned off. To avoid dam-
age caused by freezing during long shutdowns in winter, it is advisable to drain all water from the boiler, the
DHW circuit and the heating system water; or drain just the DHW circuit and add a suitable antifreeze to the
heating system, as prescribed in sec. 2.3.
NOTE
- If the sun symbol does not appear on the
display
but the multifunction numbers are present, the boiler is
in
“Winter” mode
.
1.4 Adjustments
Winter/summer switchover
Press the
winter/summer/off button
(detail 7 - fig. 1)
until the display shows the Summer symbol (detail 10
- fig. 1): the boiler will only deliver domestic hot water.
The frost protection system remains activated.
fig. 10
To reactivate the Winter mode, press the
winter/sum-
mer/off button
(detail 7 - fig. 1) twice.
fig. 11
Heating temperature adjustment
Use the heating buttons (details 3 and 4 - fig. 1) to ad-
just the temperature from a min. of 20°C to a max. of
80°C.
fig. 12