Parameter Value
Meaning
Basic
55 z
time before dialing
1
z
– time [sec] after guard lifting up before dialing [range 1-5]. This time is
different for each exchange, but most central exchanges usually manage
to process dialing up to 2 seconds after line lifting up.
List of related parameters:
8# 85
Parameter Value
Meaning
Basic
56 hh
number of rings before hanging up
12
h
– after finishing the dialing it calculates number of KVT (ringing tones). If
the number exceeds
h
value, it will hang up [range 04-99]. The dialing is
repeated in case, when the dialing mode of 2 groups is set.
List of related parameters:
47 8# 85
Parameter Value
Meaning
Basic
57 t
DTMF tone duration (tone) choice
5 (100ms)
58 m
gap duration among DTMF tones
5 (100ms)
59 f
Flash duration
1 (100ms)
50 p
pause duration / interdigit gap
8 (800ms)
t
– DTMF tone duration is determined per formula:
(entered 5) x 10 = tone duration
[ms]
[range
1-0
i.e.
60-150ms]
m
– gap duration among DTMF tones is determined per formula:
(entered 5) x 10 = gap duration
[ms]
[range
1-0
i.e.
60-150ms]
f
– Flash duration is determined per formula:
entered number x 100 = Flash duration
[ms]
[range
1-6
i.e.
100-600ms]
p
– pause duration is determined per formula:
entered number x 100 = pause duration
[ms]
[range
5-0
i.e.
500-1000ms]
–
p
time is simultaneously the duration of interdigit gap at pulse dialing.
List of related parameters:
1 2 41 8# 85