4.9 List of Presetting Parameters
parameter basic
presettings
switch 1 mode
lock m=1
switch 2 mode
lock m=1
passw.Day+Night switch 1
not
passw. Day+Night switch 2
not
passw.Day switch 1
not
passw.Day switch 2
not
passw. Night switch 1
not
passw. Night switch 2
not
switch 1 activ. from phone
55
switch 2 activ. from phone
66
closing time of switch 1 and 2
5 sec
con. by incoming call
allowed
delay among ap. during oper.
10 sec
choice
DTMF
sign of call extension
*
hanging up from phone 1 / 2
55 / 66
service password
0000
switching to day mode
11
switching to night mode
10
guard choice mode
Day/Night
keyboard connection
no
keyboard mode
dialing
number of rings of incoming call
2
max. call time
2 min
time among button presses
2 sec
time of hanging up when dialing repeated
2 sec
time before dialing
1 sec
number of rings before hanging up
12
DTMF tone duration (tone) choice
100ms
gap duration among DTMF tones
100ms
Flash duration
100ms
pause duration / interdigit gap
800ms
Note:
The minimum default setting can be customized by expected purchase
of min. 10pcs of NUDV.