Page 20
iLOFT Monitor
iLOFT Monitor
iLOFT Monitor
iLOFT Monitor
TECHNICAL FEATURES
CONNECTIONS
JP1:
JP2 :
JP2=VIDEO
NO TERM
TERM
JP1=DATA
Bin
Bout
- F1 F2
JP2 JP1
TERM
NO TERM
T Ct A SEC -
Ct
T
A
-
Bout Bin - F1 F2
SEC
JP2 JP1
No Term
Term
In
cascade systems
:
- Set up the JP1 switch in the NO TERM position on the first and mezzanine floor
monitors.
- Set up the JP1 switch in the TERM position on the last monitor (top floor).
In distribution systems, set up the JP1 switch in the NO TERM position on all the
monitors.
- When there is only one monitor
per residence, set up the JP2 switch in the NO TERM
position.
- If we have two monitors (or even a monitor and a telephone) the JP2 switch should be
set up in the TERM position on both terminals.
- Audio + Video Communication Bus (polarity free)
- Monitor/Additional Telephone Connection
Connection to next monitor/telephone on the cascade.
Additional Functions (negative output «-»).
Maximum current per F1 and F2 button: 150mA
Call Button Connection for Doors to Residences.
When the video is activated from this terminal on the monitor, it generates a voltage of
10Vdc (Auxiliary Camera Activation).
Call Extension Connection Ref. 2040.
Generates a voltage of 12Vdc for a period of 5 seconds when a call is received on
the monitor.
Bin
Bout
CT
T, -:
F1, F2:
A, -
SEC
Flush
Surface
Power Supply
Consumo
Operating Temperature
TFT
Flat Screen. 3,5 Diagonal
Resolution:
Horizontal: 480 Line TV - Vertical: 234 Line TV
Flush mounted monitor dimensions
(Height x Width x Depth)
:
197 x 131 x 60 mm / 7,7” x 5,1” x 2,3”
Pure flush mounted monitor dimensions
(Height x Width x Depth)
: 197 x 131 x 59 mm / 7,7” x 5,1” x 2,3”
Surface monitor dimensions
(Height x Width x Depth)
:
197 x 131 x 34,3 mm / 7,7” x 5,1” x 1,3”
Pure surface monitor dimensions
(Height x Width x Depth)
:
197 x 131 x 33,3 mm / 7,7” x 5,1” x 1,3”
24 Vdc
on standby
making a call
with video
with audio and video
[5 , +40 °C]
[41, +104 ºF]
34 mA
490 mA
330 mA
634 mA
Video Signal: 4.5Vpp Modulated Signal
Humidity
[0 - 90%]
WITH Induction Loop
36 mA
350 mA
250 mA
390 mA
WITHOUT Induction Loop
with audio at maximum