KS55 SERIES OPERATION MANUAL
4.4 - USB INTERFACE
The KS55 USB interface has the following general features:
•
USB specification
USB 2.0 (480Mbits/s full speed)
•
Transfer type
Bulk
•
Maximum receive/transmit endpoint size
64 bytes
•
Current consumption from USB bus
2mA max.
User has to use a standard “B” series USB connector.
4.5 - PRESENTER AND
LIGHT INDICATOR
Once the ticket has been printed and cut, the KS55 will automatically present it.
The KS55 has several presentation modes which are configured by the single command
DC3 P n
.
As for the amount of the ticket initially shown, the KS55 can be programmed as
short
or
long
. In
short
mode, only the first 3 cm (approx.) of the ticket are shown. In the
long
mode shows the whole ticket less
the last 60 mm (approx.).
FENIX recommend using the
short
mode for tickets shorter
than
18
cm, and the
long
mode for ticket
longer
than
18
cm.
If the ticket is not picked up within the collection time interval (
DC3 T n
command), before it is collected,
the user can be given a second chance to pick it up by the
2
nd
Warning option
: extracts 30mm more of
ticket (only in
short
mode) and reset the collection time one again.
With regard to the collection mode (if in any case the ticket has not been picked up), the KS55 can be
programmed so that the ticket is collected inward, into a box set by the developer, or the ticket is ejected
outward (supposedly, falls to the ground).
So that the whole presentation process is visibly more effective, KS55 has a light indicator integrated in
the presenter nozzle to be able to visually warning the user to pick up the ticket,
Using the
DC3 L n ton toff
command, color (GREEN, RED or ORANGE) and duty cycle can be
determined.
Fig.4.8.
KS55 light indicator.
In the
2
nd
Warning
phase of presentation light indicator can be controlled by the command
DC3 D n ton
toff
, similar to the previous one: color (GREEN, RED or ORANGE) and duty cycle can be determined.
14 of 66