KS55 SERIES OPERATION MANUAL
FEATURES AND PERFORMANCE
S
→ The active current format (font A / B) is set by "
ESC M n
" command, where
n
Function
<00>H <30>H
Character Font A (12 x 24) selected
<01>H <31>H Character Font B (8 x 16) selected
→ The active current table is set by the “
ESC t n
” command, where
n
Character table selected
<00>H /<30>H
Both internal table A and table B are selected.
<01>H /<31>H
External loaded table A is selected.
Internal table B is selected.
<02>H /<32>H
External loaded table B is selected.
Internal table A is selected.
<03>H /<33>H
Both external loaded table A and table B are selected.
→ Loading any external user table does not involve replacing the corresponding internal PC437.
→ Loading a new external character table involves replacing the previous one.
→ It is not allowed to change the character table or the format on the same character line.
→ All optional standard attributes are also applicable to external user tables: scaling, rotation, underline,
reverse...
LOADING EXTERNAL TABLES
→ In order to load an external table of characters the user has 3 options:
1)
Through the external table load command "
ESC & c1 c2 [name] [date]
", the user can load their own
character table.
2)
Use our
FontLoader
application through which you can load Windows TrueType fonts. TrueType
format conversion to internal 12x24 or 8x16 printer format may require adaptation of some
characters with the options available within the application.
64 of 66