KS55 SERIES OPERATION MANUAL
DC
3
D
n
ton toff
[Name]
Light indicator in the 2
nd
warning.
[Format]
ASCII
DC3 D
n
Hex
13
44
n
Decimal
19
68
n
[Range]
<00>H
≤
n
≤
<03>H
<00>H
≤
ton/toff
≤
<FF>H
[Description]
Enable/disable the light indicator while second warning.
If the second feed is enabled, after the collection time has elapsed, extracts 30mm
more of ticket and reset the collection time one again.
The
n
parameter determines the light color.
n
Light color
0
None
1
Green
2
Red
3
Orange
The time the light is on or off is set by the parameters
ton
and
toff
respectively.
The time unit is 0.01 seconds.
[Default]
n
= 0x02,
ton
= 0x32,
toff
= 0x32.
[Notes]
•
n
=0 or
ton
=0 disable the second warning.
•
These settings are saved in non volatile memory.
•
See
DC3 L n ton toff
command for examples.
[Reference] DC3 T n, DC3 D n ton toff