![Fenix Imvico EPC1100 Operation Manual Download Page 29](http://html1.mh-extra.com/html/fenix-imvico/epc1100/epc1100_operation-manual_3987605029.webp)
FENIX IMVICO EPC1100 OPERATION MANUAL
29/37
________________________________________________________________
ESC+’X’+n
X-SCALE
________________________________________________________________
Decimal codes:
<27><88><n>
Hexadecimal codes:
<1B><58><n>
Function:
This control sets the horizontal scale for the characters table.
“n” can take values from 1 to 47d.
The X-Scale command sets the characters’ new width, despite of the previous state of
the double-width mode.
Whenever double-width mode is set to ON, the characters’ new width is 2, despite of
the previous value of the X-Scale.
Whenever double-width mode is set to OFF, the characters’ new width is 1, despite of
the previous value of the X-Scale.
These commands do not affect the characters’ height.
GS + ‘k‘ + n + DATA + NUL
BAR CODE PRINT
Decimal codes:
<27><107><n><d1><d2>...<dk><0>
Hexadecimal codes:
<1D><6B><n><d1><d2>...<dk><00>
Function:
Data is converted to a bar code designated with “n”.
Lower 3 bits are valid in “n”.
When input data does not match with code systems, a bar code is not printed.
n=0
reserved
n=1
“
n=2
“
n=3
“
n=4
CODE39 (1<k<10)
GS + ‘h‘ + n
BAR CODE HEIGHT
Decimal codes:
<29><104><n>
Hexadecimal codes:
<1D><68><n>
Function:
Sets height of the bar code.
n=1 to 255
:
Height of the bar code (Unit: dot line)
n=162 (default)